TO ENTER A PROGRAM:
+
*Samples should be taken at: '''3 pm, 9 pm, 3 am, 9 am'''.
 +
*At least every '''4''' days the bottles in the sampler will need to be emptied into plastic bottles (in action packers at each site). 
 +
*These bottles need to be labeled with: '''River Name & Time of Sample'''.
 +
*Take pictures and make detailed notes of the location of the end of the suction line (i.e. where the sample is being drawn from).
  
(1) Enter Program Button
+
==TO ENTER A PROGRAM:==
(2) ''Program'' Enter
+
 
(3) ''Time'' Enter
+
*(1) Enter Program Button
(4) Time: ''6 hrs 0 min''
+
*(2) ''Program'' Enter
(5) Multiplex Samples: ''No'' Enter
+
*(3) ''Time'' Enter
(6) Sample Volume: ''1000 mL''
+
*(4) Time: ''6 hrs 0 min''
(7) Suction Head: measured from level of liquid source to the pump (cannot exceed 26 feet)
+
*(5) Multiplex Samples: ''No'' Enter
(8) Start Sampling
+
*(6) Sample Volume: ''1000 mL''
 +
*(7) Suction Head: measured from level of liquid source to the pump (cannot exceed 26 feet)
 +
*(8) Start Sampling
  
 
One sample should be taken at peak flow; can enter a start time for the program to begin so that it starts at peak flow, or a 6-hour interval from peak flow.
 
One sample should be taken at peak flow; can enter a start time for the program to begin so that it starts at peak flow, or a 6-hour interval from peak flow.
 +
 +
==EQUIPMENT NEEDED==
 +
*(1) Isco Sampler
 +
*(2) suction line
 +
*(3) power source (car battery & alligator clips or ni-cad batteries & wall charger)
 +
*(4) 1L sampling bottles

Latest revision as of 08:41, 12 May 2011

  • Samples should be taken at: 3 pm, 9 pm, 3 am, 9 am.
  • At least every 4 days the bottles in the sampler will need to be emptied into plastic bottles (in action packers at each site).
  • These bottles need to be labeled with: River Name & Time of Sample.
  • Take pictures and make detailed notes of the location of the end of the suction line (i.e. where the sample is being drawn from).

TO ENTER A PROGRAM:

  • (1) Enter Program Button
  • (2) Program Enter
  • (3) Time Enter
  • (4) Time: 6 hrs 0 min
  • (5) Multiplex Samples: No Enter
  • (6) Sample Volume: 1000 mL
  • (7) Suction Head: measured from level of liquid source to the pump (cannot exceed 26 feet)
  • (8) Start Sampling

One sample should be taken at peak flow; can enter a start time for the program to begin so that it starts at peak flow, or a 6-hour interval from peak flow.

EQUIPMENT NEEDED

  • (1) Isco Sampler
  • (2) suction line
  • (3) power source (car battery & alligator clips or ni-cad batteries & wall charger)
  • (4) 1L sampling bottles