The met station at Toolik needs to be transferred from its tripod to a tower.  The field requirements for this assignment will be outlined here.  | The met station at Toolik needs to be transferred from its tripod to a tower.  The field requirements for this assignment will be outlined here.  | ||
| − | ==   | + | ==To Bring from Fairbanks==  | 
| + | * Cabling to extend thermocouple temperature profile from old enclosure to new enclosure.  | ||
| + | * shovels for digging out buried cabling  | ||
| + | * extension cord   | ||
| + | * cable splicing tools  | ||
| + | ** soldering iron  | ||
| + | ** butane  | ||
| + | ** propane torch  | ||
| + | ** solder  | ||
| + | ** heat shrink  | ||
| + | * extra cabling  | ||
| + | * Toolbags  | ||
| + | * Extra data logger (CR1000, for any instruments that aren't transferred to the new logger on this trip and or don't reach... completely just a back up item)  | ||
| + | * small actionpacker  | ||
| + | * sled  | ||
| + | * Climbing harness  | ||
| − | New tower w/ enclosure & guy wires  | + | == Current Equipment On-Site==  | 
| − | + | * New tower w/ enclosure & guy wires  | |
| − | Garden web cam  | + | * Garden web cam  | 
| − | + | * Pluvio 1 (Currently installed but broken)  | |
| − | Pluvio 1  | + | * Met Station w/ soil thermocouples, radiation, lake sensors on rusted tripod  | 
| − | + | * New Multiplexer  | |
| − | Met Station w/ soil thermocouples, radiation, lake sensors on rusted tripod  | + | * Pluvio 2 (needs to be installed but is in the environmental data center)... has a different base than the existing one.  | 
| + | * Pluvio 2 base is inside the wyoming gauge snow fence sitting on the ground  | ||
== Goals ==  | == Goals ==  | ||
| − | + | * Mount recalibrated AT/RH sensors  | |
| − | Mount recalibrated   | + | * Move power to the new enclosure  | 
| − | + | * Transfer as much equipment as possible to new tower  | |
| − | Transfer as much equipment as possible to new tower  | + | * Leave what can't be moved at the old site  | 
| − | + | * Install Pluvio 2    | |
| − | Leave what can't be moved at the old site  | + | ** note, pluvio 1 wire is a bit short. but should be okay with pluvio 2  | 
| − | + | * Get evaporation pan working  | |
| − | Install Pluvio 2  | + | * Install new radiometer  | 
| − | + | * Tighten guy wires and level tower  | |
| − | Get   | ||
| − | |||
| − | Install new radiometer  | ||
| − | |||
| − | Tighten guy wires and level tower  | ||
== Needs ==  | == Needs ==  | ||
| + | * [[TFS Site Wiring]] / cable lengths   | ||
| + | * List cable types needed '''''?'''''  | ||
| + | * List muxes needed '''''?'''''  | ||
| − | + | ==List equipment/tools need to bring==  | |
| − | + | * Conduit  | |
| − | + | * New Program (Bob Bu has draft)  | |
| − | + | * Troubleshoot Evaporation Pan  | |
| − | + | * Figure out what needs calibration  | |
| − | |||
| − | |||
| − | Conduit  | ||
| − | |||
| − | New Program (Bob Bu has draft)  | ||
| − | |||
| − | Troubleshoot Evaporation Pan  | ||
| − | |||
| − | Figure out what needs calibration  | ||
== Updates ==  | == Updates ==  | ||
| − | + | * Pluvio 1 and Pluvio 2 use different base stands.  Make sure to include the Pluvio 2 mounting hardware!  | |
| − | + | * Evaporation pan may not be in the budget this year if the gauging unit (Campbell 21531) needs to be replaced.  | |
| − | + | * Conduit isn't an immediate priority since this depends on the final setup.  | |
| − | |||
| − | |||
Revision as of 09:44, 4 May 2013
Contents
Overview
The met station at Toolik needs to be transferred from its tripod to a tower. The field requirements for this assignment will be outlined here.
To Bring from Fairbanks
- Cabling to extend thermocouple temperature profile from old enclosure to new enclosure.
 - shovels for digging out buried cabling
 - extension cord
 - cable splicing tools
- soldering iron
 - butane
 - propane torch
 - solder
 - heat shrink
 
 - extra cabling
 - Toolbags
 - Extra data logger (CR1000, for any instruments that aren't transferred to the new logger on this trip and or don't reach... completely just a back up item)
 - small actionpacker
 - sled
 - Climbing harness
 
Current Equipment On-Site
- New tower w/ enclosure & guy wires
 - Garden web cam
 - Pluvio 1 (Currently installed but broken)
 - Met Station w/ soil thermocouples, radiation, lake sensors on rusted tripod
 - New Multiplexer
 - Pluvio 2 (needs to be installed but is in the environmental data center)... has a different base than the existing one.
 - Pluvio 2 base is inside the wyoming gauge snow fence sitting on the ground
 
Goals
- Mount recalibrated AT/RH sensors
 - Move power to the new enclosure
 - Transfer as much equipment as possible to new tower
 - Leave what can't be moved at the old site
 - Install Pluvio 2
- note, pluvio 1 wire is a bit short. but should be okay with pluvio 2
 
 - Get evaporation pan working
 - Install new radiometer
 - Tighten guy wires and level tower
 
Needs
- TFS Site Wiring / cable lengths
 - List cable types needed ?
 - List muxes needed ?
 
List equipment/tools need to bring
- Conduit
 - New Program (Bob Bu has draft)
 - Troubleshoot Evaporation Pan
 - Figure out what needs calibration
 
Updates
- Pluvio 1 and Pluvio 2 use different base stands. Make sure to include the Pluvio 2 mounting hardware!
 - Evaporation pan may not be in the budget this year if the gauging unit (Campbell 21531) needs to be replaced.