Difference between revisions of "NGEE Backup Instrumentation"

From IARC 207 Wiki
Jump to navigation Jump to search
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
 +
===In Fairbanks Stock===
 
Net Radiometer
 
Net Radiometer
 
CNR4 S/N 131352  
 
CNR4 S/N 131352  
Line 6: Line 7:
 
* LW Upper Sensor: 13.27 uV/W/m^2
 
* LW Upper Sensor: 13.27 uV/W/m^2
 
* LW Lower Sensor: 14.65 uV/W/m^2
 
* LW Lower Sensor: 14.65 uV/W/m^2
 +
** Last Update: 8/15/2014
  
 
Air Temperature / Radiation
 
Air Temperature / Radiation
 
Vaisala HMP155
 
Vaisala HMP155
 +
* S/N J0320039
 +
** Reason for removing from service: Periodic garbage data I think caused by corrosion in the electrical connector on the sensor head
 +
** Last Update: 8/15/2014
 +
* S/N J0330025
 +
** Last Update: 8/15/2014
 +
** Reason for removing from service: RH was lagging relative to the other site RHs.  Upon visiting the site, the yellow cap had not been removed at installation so I think this sensor is just fine.
 +
* S/N J0320033
 +
** Last Update: 8/15/2014
 +
** Reason for removing from service: Periodic garbage data I think caused by corrosion in the electrical connector on the sensor head
 +
 +
===Deployed===
 +
* S/N K0810043 Factory Calibrated 2/17/2014 Installed at: 1.4m A Site
 
* S/N K0810046 Factory Calibrated 2/17/2014 Installed at:
 
* S/N K0810046 Factory Calibrated 2/17/2014 Installed at:
* S/N K0810043 Factory Calibrated 2/17/2014 Installed at: 1.4m A Site
+
 
 +
 
 +
==Fall 2014 Snow Sensor Deployment==
 +
SDI 12 ID7
 +
* S/N 2012
 +
* S/N 3527
 +
* S/N 1439
 +
* S/N 2901
 +
SDI 12 ID 8
 +
* S/N 4516
 +
* S/N 3943
 +
* S/N 3969
 +
* S/N 3538
 +
SDI 12 ID 9
 +
* S/N 3544

Latest revision as of 16:44, 15 August 2014

In Fairbanks Stock

Net Radiometer CNR4 S/N 131352

  • Purchased 8/2014 Factory Calibrated 1/1/2013
  • SW Upper Sensor: 12.64 uV/W/m^2
  • SW Lower Sensor: 12.69 uV/W/m^2
  • LW Upper Sensor: 13.27 uV/W/m^2
  • LW Lower Sensor: 14.65 uV/W/m^2
    • Last Update: 8/15/2014

Air Temperature / Radiation Vaisala HMP155

  • S/N J0320039
    • Reason for removing from service: Periodic garbage data I think caused by corrosion in the electrical connector on the sensor head
    • Last Update: 8/15/2014
  • S/N J0330025
    • Last Update: 8/15/2014
    • Reason for removing from service: RH was lagging relative to the other site RHs. Upon visiting the site, the yellow cap had not been removed at installation so I think this sensor is just fine.
  • S/N J0320033
    • Last Update: 8/15/2014
    • Reason for removing from service: Periodic garbage data I think caused by corrosion in the electrical connector on the sensor head

Deployed

  • S/N K0810043 Factory Calibrated 2/17/2014 Installed at: 1.4m A Site
  • S/N K0810046 Factory Calibrated 2/17/2014 Installed at:


Fall 2014 Snow Sensor Deployment

SDI 12 ID7

  • S/N 2012
  • S/N 3527
  • S/N 1439
  • S/N 2901

SDI 12 ID 8

  • S/N 4516
  • S/N 3943
  • S/N 3969
  • S/N 3538

SDI 12 ID 9

  • S/N 3544