Difference between revisions of "Spring 2016 site visit"

From IARC 207 Wiki
Jump to navigation Jump to search
Line 4: Line 4:
  
 
*install new evap pan
 
*install new evap pan
**bring marine epoxy in case there is a leak
+
**leak test (marine epoxy in case
 +
**clean out bottom
 
*swap in fancier wind sensor
 
*swap in fancier wind sensor
 
*fill in serial numbers of all instruments/loggers on google sheet
 
*fill in serial numbers of all instruments/loggers on google sheet
Line 43: Line 44:
 
**tools
 
**tools
 
**marine epoxy
 
**marine epoxy
 +
**wire junction
 
**hiking boots,rubber boots
 
**hiking boots,rubber boots
 
**instruments
 
**instruments
 
***anemometer
 
***anemometer
 
***CNR4
 
***CNR4

Revision as of 13:00, 2 June 2016

  • take photos of sensors without pics on instrumentation site
  • bring measuring cup set for leveling UVA and UVB sensors
  • wire junction to split all instruments needing 12V from logger
  • install new evap pan
    • leak test (marine epoxy in case
    • clean out bottom
  • swap in fancier wind sensor
  • fill in serial numbers of all instruments/loggers on google sheet
  • calibrate tipping bucket
    • fill bottle to line, use smallest orifice, do this 3 times
    • should be 30mm per bottle, so 90mm total
    • change multiplier in program if necessary
  • do accuracy test on Pluvio
    • received software in ftp from ott (on my fancy laptop, need to transfer to toughbook)
    • need usb cable
  • CANOE out to figure all of underwater sensors out!
    • inspect pressure transducer and change desiccant
    • figure out what is measuring temperature
    • swap underwater quantum
  • swap out HMP155s
  • swap out quantum sensors
    • bring mini wrench to replace them
    • figure out what the connection is like at toolik
    • change calibration constant?
  • download garden cam images
    • bring replacement batteries
  • we zero out the CMP6, but not the CNR4. reconsider?
  • swap CNR4
    • change program calibration constants
  • change UVA + UVB program calibration constants: UVA:0.0221, UVB: 0.00178 (per Lija's email)
  • remove old radio
  • get field books from Brie
  • To change on instrumentation website
    • pluvio is actually version 2
    • lake temp measurement
    • barometer
  • to bring
    • laptop + charger
    • tipping bucket calibration box
    • gloves, hat(warm and sun)
    • tools
    • marine epoxy
    • wire junction
    • hiking boots,rubber boots
    • instruments
      • anemometer
      • CNR4