Difference between revisions of "Spring 2016 site visit"

From IARC 207 Wiki
Jump to navigation Jump to search
 
(3 intermediate revisions by 2 users not shown)
Line 4: Line 4:
 
*leak test (marine epoxy in case of leaks. should be up in the EDC office)
 
*leak test (marine epoxy in case of leaks. should be up in the EDC office)
 
*clean out bottom
 
*clean out bottom
 +
*float should hang from the right side of the sprocket wheel with the counter-weight to the left side of the wheel. A white line is painted on the front of the sprocket, When viewed from the front side, the line should be at the 11 o’clock or 30° when the float is resting on the bottom of the
 +
gauge.
 
*field calibrate
 
*field calibrate
  
Line 115: Line 117:
 
*zip ties
 
*zip ties
 
*2 crossarm mounting kits for wind sensors
 
*2 crossarm mounting kits for wind sensors
*mesh for shield for pluvio
+
*teflon tape
 +
*tape for pulling wire through conduit
 +
*spare wire
 +
*spare campbell flathead
 +
*lense cloth for radiometer
  
 
==accomplished==
 
==accomplished==
Line 131: Line 137:
 
::read 81.27 mm for 3 bottles instead of 90. => multiplied multiplier by 1.107. new multiplier = 0.281
 
::read 81.27 mm for 3 bottles instead of 90. => multiplied multiplier by 1.107. new multiplier = 0.281
 
*swapped barometer
 
*swapped barometer
*rewired 12V and G into wire junction so easier to wire
+
*added wire junction to 12V and G ports on CR3000 so easier to wire
 
*re-wired new wind sensor
 
*re-wired new wind sensor
 
*replaced garden cam batteries
 
*replaced garden cam batteries
 +
 +
June 10, 2016
 +
*set up evap pan
 +
:: requires ~12 5 gal jugs (borrowed jugs from sauna, got water from the Shower building)
 +
*sent new program
 +
*began dismantle of auxiliary snow station
 +
::removed enclosures, loggers, sr50a, radios, antennas, etc.
 +
::coiled power and ethernet cable to near Jeb's room, but couldn't pull through the conduit under the road
 +
::ethernet plugged into 201 cotton grass.
  
 
==Tomorrow==
 
==Tomorrow==
Line 142: Line 157:
 
==post trip==
 
==post trip==
 
*calibrate swapped sensors
 
*calibrate swapped sensors
 +
**Tested the removed wind sensor (5106 marine version) with our RM Young calibration supplies on 7/27/16
 +
***propeller torque turns at 0.5 gm-cm (spec is 2.6)
 +
***vane torque moves at 20 gm-cm (spec is 30)
 +
***speed matches RPMs with anemometer drive
 +
***direction is off by 2 degrees (reads 118 when it should be 120)
 
*troubleshoot wind speed and air temp jumps
 
*troubleshoot wind speed and air temp jumps
 
*update website and spreadsheet with SN and calibration swap dates
 
*update website and spreadsheet with SN and calibration swap dates
 
*think about pressure
 
*think about pressure
 
*mesh for pluvio
 
*mesh for pluvio

Latest revision as of 10:53, 27 July 2016

Head up June 7th, 2016

install new evap pan

  • leak test (marine epoxy in case of leaks. should be up in the EDC office)
  • clean out bottom
  • float should hang from the right side of the sprocket wheel with the counter-weight to the left side of the wheel. A white line is painted on the front of the sprocket, When viewed from the front side, the line should be at the 11 o’clock or 30° when the float is resting on the bottom of the

gauge.

  • field calibrate
   Fill pan partway with water, measure height with ruler in mm
   Measure voltage by reading the EvapLevelTemp variable on the program
   Add more water, measure water depth in pan
   Measure voltage
   Calculate multiplier and offset using y = mx+b
       m(multiplier) = (height1-height2)/(voltage2-voltage1)
       b(offset) = height1-(m*voltage1)

calibrate precip

Tipping bucket

  • fill bottle to line, use smallest orifice, do this 3 times
  • should be 30mm per bottle, so 90mm total
  • change multiplier in program if necessary

Pluvio accuracy test

  • received software in ftp from ott (on my fancy laptop, need to transfer to toughbook)
  • need usb cable

Brie Helps with

  • swap in fancier wind sensor 5108-45-12M
shouldn't need to re-align if don't move he orientation ring
wiring slightly different
  • swap out HMP155s
    • write down which height is which SN
  • download garden cam images
    • bring replacement batteries
    • to turn off: press and hold organge power button until 3 beeps and green LED turns off
    • remove drive, download and clear images on computer
    • to turn on:press and hold organge power button until green LED lights up. after a few sec beep twice. green LED every 15 sec indicates normal running. if any other beeping or lights, consult manual

additional tasks

  • wire junction to split all instruments needing 12V from logger
  • swap out quantum sensors
    • bring mini wrench to replace them
    • figure out what the connection is like at toolik
    • change calibration constant?
  • remove old radio
  • get field books from Brie
  • swap CNR4, change program constants
  • install new barometer, change program constants
  • level radiometers + tipping bucket
  • Take down auxiliary snow station
    • get data off of logger, wind up power and ethernet, etc

take photos of sensors without pics on instrumentation site

  • HMP155
  • wind sensors
  • snow dept
  • barometer
  • evap pan

program changes

  • evap pan calibration
  • possible tipping bucket calibration
  • possible pluvio calibration
  • UVA+UVB corrections. UVA:0.0221, UVB: 0.00178 (per Lija's email)
  • barometer mult and offset changes (+85 to offset for elevation difference)
  • CNR4 constants
LW up: 7.51
LW down: 8.24
SW up: 16.77
SW down: 14.82
  • 5108 WS multiplier, 0.1666
  • we zero out the CMP6, but not the CNR4. reconsider?

get SN of all instruments/loggers on google sheet

  • datalogger,mux, radios, nl__
  • both wind sensors,cmp4, cmp6, evap gauge, precips
  • basically everything

To change on instrumentation website

  • pluvio is actually version 2
  • lake temp measurement
  • barometer
  • ask ed to put 2015 met report up

to bring

  • laptop + charger
  • field laptop + charger
  • tipping bucket calibration box
  • gloves, hat(warm and sun)
  • tools (level, compass, small wrench for quantum)
  • wire junction
  • hiking boots,rubber boots,running shoes
  • field book, regular notebook
  • usb cable for pluvio
  • batteries for garden cam
  • measuring cup set for leveling UVA and UVB sensors
  • cookies for brie
  • instruments
    • anemometer
    • CNR4
    • Two HMP155s
    • baromter
    • quantum

to purchase

  • action packers
  • AA batteries
  • scrubby for the evaporation pan

should have had

  • electrical tape
  • snips
  • crimper (where did it go?)
  • rectangle level
  • larger crescent wrench
  • zip ties
  • 2 crossarm mounting kits for wind sensors
  • teflon tape
  • tape for pulling wire through conduit
  • spare wire
  • spare campbell flathead
  • lense cloth for radiometer

accomplished

June 8, 2016

  • swapped both HMP155
  • swapped 5108 for 5106. the crossarm had rotated. brie re-levelled it and secured it with better crossarm mounting bracket (need to purchase another). and consider moving the bar next time we swap a sensor.
  • downloaded garden cam images, cleared flashdrive, replaced upper batteries, need to replace lower ones.
  • emptied pluvio
    • pluvio software WORKS when connected to pluvio! calibrate tomorrow

June 9, 2016

  • swapped quantum
  • swapped CNR4
  • Calibrated tipping bucket
read 81.27 mm for 3 bottles instead of 90. => multiplied multiplier by 1.107. new multiplier = 0.281
  • swapped barometer
  • added wire junction to 12V and G ports on CR3000 so easier to wire
  • re-wired new wind sensor
  • replaced garden cam batteries

June 10, 2016

  • set up evap pan
requires ~12 5 gal jugs (borrowed jugs from sauna, got water from the Shower building)
  • sent new program
  • began dismantle of auxiliary snow station
removed enclosures, loggers, sr50a, radios, antennas, etc.
coiled power and ethernet cable to near Jeb's room, but couldn't pull through the conduit under the road
ethernet plugged into 201 cotton grass.

Tomorrow

post trip

  • calibrate swapped sensors
    • Tested the removed wind sensor (5106 marine version) with our RM Young calibration supplies on 7/27/16
      • propeller torque turns at 0.5 gm-cm (spec is 2.6)
      • vane torque moves at 20 gm-cm (spec is 30)
      • speed matches RPMs with anemometer drive
      • direction is off by 2 degrees (reads 118 when it should be 120)
  • troubleshoot wind speed and air temp jumps
  • update website and spreadsheet with SN and calibration swap dates
  • think about pressure
  • mesh for pluvio