Difference between revisions of "Oliktok precip site"
Jump to navigation
Jump to search
(Created page with "Geonor notes *needs antifreeze sol'n: Propylene glycol (40%) / Methanol (60%) *needs 0.4L Low Pour Hydraulic oil") |
|||
Line 2: | Line 2: | ||
*needs antifreeze sol'n: Propylene glycol (40%) / Methanol (60%) | *needs antifreeze sol'n: Propylene glycol (40%) / Methanol (60%) | ||
*needs 0.4L Low Pour Hydraulic oil | *needs 0.4L Low Pour Hydraulic oil | ||
+ | |||
+ | Power | ||
+ | *LPM uses max 150 VA (VA = watts) | ||
+ | *Geonor heater draws 25 watts at 24 volts | ||
+ | **3.4 mA per vibrating wire. 7 mA on warm up | ||
+ | *SR50a | ||
+ | **250 mA peak measurement (measurement takes less than 1 sec) | ||
+ | **1 mA quiescent in SDI12 mode |
Revision as of 11:32, 28 July 2016
Geonor notes
- needs antifreeze sol'n: Propylene glycol (40%) / Methanol (60%)
- needs 0.4L Low Pour Hydraulic oil
Power
- LPM uses max 150 VA (VA = watts)
- Geonor heater draws 25 watts at 24 volts
- 3.4 mA per vibrating wire. 7 mA on warm up
- SR50a
- 250 mA peak measurement (measurement takes less than 1 sec)
- 1 mA quiescent in SDI12 mode