Difference between revisions of "Oliktok precip site"
Jump to navigation
Jump to search
imported>Lilyrachelc |
|||
Line 2: | Line 2: | ||
*needs antifreeze sol'n: Propylene glycol (40%) / Methanol (60%) | *needs antifreeze sol'n: Propylene glycol (40%) / Methanol (60%) | ||
*needs 0.4L Low Pour Hydraulic oil | *needs 0.4L Low Pour Hydraulic oil | ||
+ | *Geonor fence | ||
+ | **Alter shield | ||
+ | ***attach shield to Geonor stand with 1in pipe, then 1in to 3/4in nurail offset cross fitting like (http://www.nurail.com/products/%2310-Offset-Cross-%252d-3%7B47%7D4in-x-1in..html), then 3/4in post provided with the alter shield | ||
Power | Power |
Revision as of 16:23, 3 August 2016
Geonor notes
- needs antifreeze sol'n: Propylene glycol (40%) / Methanol (60%)
- needs 0.4L Low Pour Hydraulic oil
- Geonor fence
- Alter shield
- attach shield to Geonor stand with 1in pipe, then 1in to 3/4in nurail offset cross fitting like (http://www.nurail.com/products/%2310-Offset-Cross-%252d-3%7B47%7D4in-x-1in..html), then 3/4in post provided with the alter shield
- Alter shield
Power
- LPM uses max 150 VA (VA = watts)
- Geonor heater draws 25 watts at 24 volts
- 3.4 mA per vibrating wire. 7 mA on warm up
- SR50a
- 250 mA peak measurement (measurement takes less than 1 sec)
- 1 mA quiescent in SDI12 mode
Site Location