Difference between revisions of "Oliktok summer 2017 trip"
Jump to navigation
Jump to search
(Created page with "*replace sr50a transducers") |
|||
| (6 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
| + | ===for telayna=== | ||
*replace sr50a transducers | *replace sr50a transducers | ||
| + | **1)unscrew sensor from mount | ||
| + | **2)unscrew cable from sensor | ||
| + | **3)unscrew all little screws holding the transducer to the sensor body (use the frisbee to work so you don't lose the little screws) | ||
| + | **4)unclip the wires of the old transducer, remove the O ring | ||
| + | **5)place desiccant in the new transducer | ||
| + | **5)place the new O ring on the sensor body and clip the new transducer wire | ||
| + | **6)line up the notch of the new transducer on the sensor body | ||
| + | **7)screw in all the little screws | ||
| + | **8)replace the sensor on the mount and screw in the cable (which is notched) | ||
| + | |||
| + | |||
| + | *put up temperature sensor | ||
| + | **1)mount it on the south side of the fence | ||
| + | **2)plug sensor into sensor head | ||
| + | **3)screw | ||
| + | **4)zip tie cable to make things neat | ||
| + | **5)unplug logger before wiring | ||
| + | **wiring to CR1000 logger | ||
| + | ***Red -- SW-12 | ||
| + | ***yellow -- SE11 | ||
| + | ***blue -- SE12 | ||
| + | ***clear -- AG | ||
| + | ***black -- AG | ||
| + | ***white -- AG | ||
| + | **replace putty | ||
| + | **replace power to logger | ||
| + | |||
| + | *CFM100 | ||
| + | **1)unplug power from logger | ||
| + | **2)plug and screw in the CFM100 | ||
| + | **3)re-plug power to the logger | ||
| + | **4)insert card | ||
| + | |||
| + | *level geonor | ||
| + | **there are screws at the base | ||
| + | **need to remove cover to access them- and maybe bucket as well | ||
| + | **don't do this if it doesn't seem obvious | ||
| + | |||
| + | *visually inspect panes of LPM | ||
| + | **IF dirty: wipe them with a paper towel or the alcohol swabbies I sent with you | ||
| + | |||
| + | *tools i'm sending you with | ||
| + | **7/16 nut driver | ||
| + | **small flathead screw driver | ||
| + | **small Philips screw driver | ||
| + | **adjustable wrench | ||
| + | **channel locks | ||
| + | |||
| + | ===other=== | ||
| + | *antifreeze | ||
| + | *<s>snip vegetation underneath | ||
| + | **cable housing | ||
| + | *plastic cable covers for all cables entering into the logger?</s> | ||
Latest revision as of 16:14, 7 September 2017
for telayna
- replace sr50a transducers
- 1)unscrew sensor from mount
- 2)unscrew cable from sensor
- 3)unscrew all little screws holding the transducer to the sensor body (use the frisbee to work so you don't lose the little screws)
- 4)unclip the wires of the old transducer, remove the O ring
- 5)place desiccant in the new transducer
- 5)place the new O ring on the sensor body and clip the new transducer wire
- 6)line up the notch of the new transducer on the sensor body
- 7)screw in all the little screws
- 8)replace the sensor on the mount and screw in the cable (which is notched)
- put up temperature sensor
- 1)mount it on the south side of the fence
- 2)plug sensor into sensor head
- 3)screw
- 4)zip tie cable to make things neat
- 5)unplug logger before wiring
- wiring to CR1000 logger
- Red -- SW-12
- yellow -- SE11
- blue -- SE12
- clear -- AG
- black -- AG
- white -- AG
- replace putty
- replace power to logger
- CFM100
- 1)unplug power from logger
- 2)plug and screw in the CFM100
- 3)re-plug power to the logger
- 4)insert card
- level geonor
- there are screws at the base
- need to remove cover to access them- and maybe bucket as well
- don't do this if it doesn't seem obvious
- visually inspect panes of LPM
- IF dirty: wipe them with a paper towel or the alcohol swabbies I sent with you
- tools i'm sending you with
- 7/16 nut driver
- small flathead screw driver
- small Philips screw driver
- adjustable wrench
- channel locks
other
- antifreeze
snip vegetation underneath- cable housing
plastic cable covers for all cables entering into the logger?