* Reset All sky cameras... should think about moving them to a UPS.... | * Reset All sky cameras... should think about moving them to a UPS.... | ||
* hauled out 12V batteries and battery charger for replacement backup system | * hauled out 12V batteries and battery charger for replacement backup system | ||
Line 9: | Line 11: | ||
* Gill Instruments 1561-PK-020 ultrasonic anemometer | * Gill Instruments 1561-PK-020 ultrasonic anemometer | ||
** forest floor s/n 100603 | ** forest floor s/n 100603 | ||
+ | |||
+ | (and 8/4) | ||
+ | * swapped lowest AT/RH | ||
+ | * In: K4220036 2014 calibration (but never used) | ||
+ | * out: G4020001 | ||
+ | * Reset HR4000 laptop. |
Latest revision as of 15:09, 4 August 2017
- Reset All sky cameras... should think about moving them to a UPS....
- hauled out 12V batteries and battery charger for replacement backup system
- I think one battery may be too old.
- also brought out the cigarette adapters. IThere are two 12 Volt power supplies out there. One is 15 amps and the other is 19 amps.
- 8 010C Anemometers to calibrate
- 9 HMP155 AT/RH to calibrate
- SI111 is s/n 2517 made 26-Feb-2010
- Gill Instruments 1561-PK-020 ultrasonic anemometer
- forest floor s/n 100603
(and 8/4)
- swapped lowest AT/RH
- In: K4220036 2014 calibration (but never used)
- out: G4020001
- Reset HR4000 laptop.