Difference between revisions of "Dbm8"

From IARC 207 Wiki
Jump to navigation Jump to search
imported>Ken
 
imported>Ken
Line 2: Line 2:
  
 
{{todo}}
 
{{todo}}
 +
 +
* '''TAKE SR50 cable''' to site, estimated 40-feet ('''but check design specs!''')
 +
  
 
=site logs=
 
=site logs=
 +
 +
== 14 June 2007, Ken I., Doug K. ==
 +
 +
* net radiometer replaced
 +
** s/n 052046
 +
** 14.6 uV/W-m^2
 +
** 120 cm centerline sensor to ground
 +
 +
* SR50 -- cable missing, not replaced (had one, but too short)
 +
 +
* RMYoung & HMP45C cables put in flex conduit on tripod
 +
 +
* no GWS-YSI sensor, and no conduit was left for it
 +
 +
* AT shields braced with mast/enclosure bracket to strengthen
 +
 +
* antenna cable wrapped with nylon spiral wrap; no way to pull into conduit
 +
 +
* conduits '''wired''' (using tie-wire) to enclosure entry fittings to secure
 +
 +
* soil temp profile cable: added strain relief using hose clamp & cord; load was on the multiplexer terminals
 +
 +
* added cord inside enclosure to secure extra/loose cables inside
 +
 +
* replaced rain gauge
 +
** model: TR-525USW
 +
** s/n: 37655-1205
 +
** collector/funnel secured with hose clamp
 +
** screen secured with electrical tape
 +
 +
 +
 +
  
 
== 13 June 2007, Ken I., Doug K. ==
 
== 13 June 2007, Ken I., Doug K. ==

Revision as of 11:19, 3 July 2007

Bullen Point met

site TODO list

  • record as-built wiring of soil sensors
  • Flex conduit as needed
  • TAKE SR50 cable to site, estimated 40-feet (but check design specs!)


site logs

14 June 2007, Ken I., Doug K.

  • net radiometer replaced
    • s/n 052046
    • 14.6 uV/W-m^2
    • 120 cm centerline sensor to ground
  • SR50 -- cable missing, not replaced (had one, but too short)
  • RMYoung & HMP45C cables put in flex conduit on tripod
  • no GWS-YSI sensor, and no conduit was left for it
  • AT shields braced with mast/enclosure bracket to strengthen
  • antenna cable wrapped with nylon spiral wrap; no way to pull into conduit
  • conduits wired (using tie-wire) to enclosure entry fittings to secure
  • soil temp profile cable: added strain relief using hose clamp & cord; load was on the multiplexer terminals
  • added cord inside enclosure to secure extra/loose cables inside
  • replaced rain gauge
    • model: TR-525USW
    • s/n: 37655-1205
    • collector/funnel secured with hose clamp
    • screen secured with electrical tape



13 June 2007, Ken I., Doug K.

  • installed electric fence with 3 posts
  • no time to fix site cables
  • LOTS of fox scat around site, many chewed cables