= Bullen Point met = | = Bullen Point met = | ||
− | + | ||
+ | |||
+ | * return/replace site logbook to enclosure | ||
=site logs= | =site logs= | ||
+ | |||
+ | == 9 Sept 2008, 2:40pm ADT Emily == | ||
+ | *SR50 sensor looks good | ||
+ | *SR50 distance to ground before trimming vegetation was ~104 cm | ||
+ | *Trimmed vegetation and added bark chips, new average distance is ~102 cm | ||
+ | *Updated program (old program Sr50 offset is 112 cm, new value is 102 cm) | ||
+ | *tightened fence and guy wires to radiation and SR50 poles | ||
+ | |||
+ | == 14 Jun 2008, 12:00pm ADT Emily and Ken == | ||
+ | * replaced snow sensor. Old s/n 4800, new s/n C2333 | ||
+ | * measured distance from ground to sensor | ||
+ | **old distance was 112cm, new distance is the same | ||
+ | * rewired soil moisture sensors: wiring is as follows: | ||
+ | ** bl-bl, red-red, gre-gre, oran-white | ||
+ | * added conduit | ||
+ | |||
+ | == 29 Aug2007, Ken I.== | ||
+ | Transcribed by EKY | ||
+ | * SR50 replaced old w/ new SR50M-45, S/N C4800 PROM SR50V13, SIG 56809 | ||
+ | * Used Rob's 45' lead | ||
+ | * Repulled YSIx3 soil temp surface sensors | ||
+ | * Installed new YSIx3 sensors but 2 of 3 were bad | ||
+ | * all cables are in conduit | ||
+ | * SR50 to ground distance is 108, but grass is 10-18 cm higher | ||
+ | * tightened electric fence, but....? | ||
+ | |||
+ | |||
+ | |||
+ | == 14 June 2007, Ken I., Doug K. == | ||
+ | |||
+ | * net radiometer replaced | ||
+ | ** s/n 052046 | ||
+ | ** 14.6 uV/W-m^2 | ||
+ | ** 120 cm centerline sensor to ground | ||
+ | |||
+ | * SR50 -- cable missing, not replaced (had one, but too short) | ||
+ | |||
+ | * RMYoung & HMP45C cables put in flex conduit on tripod | ||
+ | |||
+ | * no GWS-YSI sensor, and no conduit was left for it | ||
+ | |||
+ | * AT shields braced with mast/enclosure bracket to strengthen | ||
+ | |||
+ | * antenna cable wrapped with nylon spiral wrap; no way to pull into conduit | ||
+ | |||
+ | * conduits '''wired''' (using tie-wire) to enclosure entry fittings to secure | ||
+ | * soil temp profile cable: added strain relief using hose clamp & cord; load was on the multiplexer terminals | ||
+ | * added cord inside enclosure to secure extra/loose cables inside | ||
+ | * replaced rain gauge | ||
+ | ** model: TR-525USW | ||
+ | ** s/n: 37655-1205 | ||
+ | ** collector/funnel secured with hose clamp | ||
+ | ** screen secured with electrical tape | ||
+ | |||
== 13 June 2007, Ken I., Doug K. == | == 13 June 2007, Ken I., Doug K. == | ||
* installed electric fence with 3 posts | * installed electric fence with 3 posts | ||
− | |||
* no time to fix site cables | * no time to fix site cables | ||
− | |||
* '''LOTS''' of fox scat around site, many chewed cables | * '''LOTS''' of fox scat around site, many chewed cables | ||
+ | * accidentally removed site logbook |
Latest revision as of 12:39, 17 September 2008
Contents
Bullen Point met
- return/replace site logbook to enclosure
site logs
9 Sept 2008, 2:40pm ADT Emily
- SR50 sensor looks good
- SR50 distance to ground before trimming vegetation was ~104 cm
- Trimmed vegetation and added bark chips, new average distance is ~102 cm
- Updated program (old program Sr50 offset is 112 cm, new value is 102 cm)
- tightened fence and guy wires to radiation and SR50 poles
14 Jun 2008, 12:00pm ADT Emily and Ken
- replaced snow sensor. Old s/n 4800, new s/n C2333
- measured distance from ground to sensor
- old distance was 112cm, new distance is the same
- rewired soil moisture sensors: wiring is as follows:
- bl-bl, red-red, gre-gre, oran-white
- added conduit
29 Aug2007, Ken I.
Transcribed by EKY
- SR50 replaced old w/ new SR50M-45, S/N C4800 PROM SR50V13, SIG 56809
- Used Rob's 45' lead
- Repulled YSIx3 soil temp surface sensors
- Installed new YSIx3 sensors but 2 of 3 were bad
- all cables are in conduit
- SR50 to ground distance is 108, but grass is 10-18 cm higher
- tightened electric fence, but....?
14 June 2007, Ken I., Doug K.
- net radiometer replaced
- s/n 052046
- 14.6 uV/W-m^2
- 120 cm centerline sensor to ground
- SR50 -- cable missing, not replaced (had one, but too short)
- RMYoung & HMP45C cables put in flex conduit on tripod
- no GWS-YSI sensor, and no conduit was left for it
- AT shields braced with mast/enclosure bracket to strengthen
- antenna cable wrapped with nylon spiral wrap; no way to pull into conduit
- conduits wired (using tie-wire) to enclosure entry fittings to secure
- soil temp profile cable: added strain relief using hose clamp & cord; load was on the multiplexer terminals
- added cord inside enclosure to secure extra/loose cables inside
- replaced rain gauge
- model: TR-525USW
- s/n: 37655-1205
- collector/funnel secured with hose clamp
- screen secured with electrical tape
13 June 2007, Ken I., Doug K.
- installed electric fence with 3 posts
- no time to fix site cables
- LOTS of fox scat around site, many chewed cables
- accidentally removed site logbook