Difference between revisions of "Dbm8"

From IARC 207 Wiki
Jump to navigation Jump to search
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
= Bullen Point met =
 
= Bullen Point met =
  
{{todo}}
 
  
* '''TAKE SR50 cable''' to site, estimated 40-feet ('''but check design specs!''')
+
 
 
* return/replace site logbook to enclosure
 
* return/replace site logbook to enclosure
  
 
=site logs=
 
=site logs=
 +
 +
== 9 Sept 2008, 2:40pm ADT Emily ==
 +
*SR50 sensor looks good
 +
*SR50 distance to ground before trimming vegetation was ~104 cm
 +
*Trimmed vegetation and added bark chips, new average distance is ~102 cm
 +
*Updated program (old program Sr50 offset is 112 cm, new value is 102 cm)
 +
*tightened fence and guy wires to radiation and SR50 poles
 +
 +
== 14 Jun 2008, 12:00pm ADT Emily and Ken ==
 +
* replaced snow sensor.  Old s/n 4800, new s/n C2333
 +
* measured distance from ground to sensor
 +
**old distance was 112cm, new distance is the same
 +
* rewired soil moisture sensors:  wiring is as follows:
 +
** bl-bl, red-red, gre-gre, oran-white
 +
* added conduit
 +
 
== 29 Aug2007, Ken I.==
 
== 29 Aug2007, Ken I.==
 
Transcribed by EKY
 
Transcribed by EKY

Latest revision as of 12:39, 17 September 2008

Bullen Point met

  • return/replace site logbook to enclosure

site logs

9 Sept 2008, 2:40pm ADT Emily

  • SR50 sensor looks good
  • SR50 distance to ground before trimming vegetation was ~104 cm
  • Trimmed vegetation and added bark chips, new average distance is ~102 cm
  • Updated program (old program Sr50 offset is 112 cm, new value is 102 cm)
  • tightened fence and guy wires to radiation and SR50 poles

14 Jun 2008, 12:00pm ADT Emily and Ken

  • replaced snow sensor. Old s/n 4800, new s/n C2333
  • measured distance from ground to sensor
    • old distance was 112cm, new distance is the same
  • rewired soil moisture sensors: wiring is as follows:
    • bl-bl, red-red, gre-gre, oran-white
  • added conduit

29 Aug2007, Ken I.

Transcribed by EKY

  • SR50 replaced old w/ new SR50M-45, S/N C4800 PROM SR50V13, SIG 56809
  • Used Rob's 45' lead
  • Repulled YSIx3 soil temp surface sensors
  • Installed new YSIx3 sensors but 2 of 3 were bad
  • all cables are in conduit
  • SR50 to ground distance is 108, but grass is 10-18 cm higher
  • tightened electric fence, but....?


14 June 2007, Ken I., Doug K.

  • net radiometer replaced
    • s/n 052046
    • 14.6 uV/W-m^2
    • 120 cm centerline sensor to ground
  • SR50 -- cable missing, not replaced (had one, but too short)
  • RMYoung & HMP45C cables put in flex conduit on tripod
  • no GWS-YSI sensor, and no conduit was left for it
  • AT shields braced with mast/enclosure bracket to strengthen
  • antenna cable wrapped with nylon spiral wrap; no way to pull into conduit
  • conduits wired (using tie-wire) to enclosure entry fittings to secure
  • soil temp profile cable: added strain relief using hose clamp & cord; load was on the multiplexer terminals
  • added cord inside enclosure to secure extra/loose cables inside
  • replaced rain gauge
    • model: TR-525USW
    • s/n: 37655-1205
    • collector/funnel secured with hose clamp
    • screen secured with electrical tape


13 June 2007, Ken I., Doug K.

  • installed electric fence with 3 posts
  • no time to fix site cables
  • LOTS of fox scat around site, many chewed cables
  • accidentally removed site logbook