- Primarily troubleshooting the anemometers.
- determined that the tower one is outputting and output is being received by LI7550.
- Bottom unit is outputing but all winds are zero through rs232 interface and also the analog interface.
- complicating things a bit, the lower interface box doesn't seem to have the capacity to log digital?? so I'm going to move the tower unit to the forest floor and then rewire the tower for digital.
- that should get something....
- Also there is still closer to 100% snow cover.