Difference between revisions of "NGEE Teller Bottom Notes"
Jump to navigation
Jump to search
Line 48: | Line 48: | ||
* 2018 heat flux plates look decent. | * 2018 heat flux plates look decent. | ||
** it could be that top & bottom are flipped and also that what should be the top is actually flipped in sign?...need to compare to top. | ** it could be that top & bottom are flipped and also that what should be the top is actually flipped in sign?...need to compare to top. | ||
+ | *** 2021-05 Update: Yes I think this is true after putting all flux plates on same plot. | ||
* VATP | * VATP | ||
** Blip during station visit at 6/13/2018 21:00 | ** Blip during station visit at 6/13/2018 21:00 |
Revision as of 17:24, 10 May 2021
Contents
Latest
- Met Data QA'd through: 9/24/2018
- Radiation Data QA'd through: 9/24/2018
- Soil through:
- Snow profile through:
- Snow through: 2016-2017 season
- Spectral through:
Met
Met 2016
- All fixed prior to start of this page... I'll go back and add notes as time allows.
- But, station put up in early April 2016 as a temporary setup on a
- Summer Precip Ends: 11/04/2016 02:00
- Need to revisit data grouper to address the pandas change with respect to NAN and averaging. 10/12/2018 (for AT/RH/DP in 2016 April)
Met 2017
- all good / corrected... same as above, I will add notes later.
- Last Winter Season Precip: 04/21/2017 18:00
- Start of Winter Season for Precip: 10/15/2017 13:00
Met 2018
- Barometric Pressure good through 6/2018 visit
- Wind Speed & Direction good through 6/2018 visit
- Air Temperature / Dewpoint / Relative Humidity good through 6/2018 visit
- Rain Gage destroyed by moose 12/25/2017.
- Bucket fixed 6/13/2018 around 21:00 - 22:00 (tips in data were test tips with new bucket).
- QA file reflects this.
Radiation
Radiation 2016
- all good / corrected
Radiation 2017
- all good / corrected
Radiation 2018
- SW & LW & Skin Temp look good through 6/2018 visit.
Soil
- I need to dig into the fieldbook notes to see if the VATP jacked at all in 2017.
Soil 2016
Soil 2017
- Heat Flux plates nonworking until 10/2017
Soil 2018
- 2018 heat flux plates look decent.
- it could be that top & bottom are flipped and also that what should be the top is actually flipped in sign?...need to compare to top.
- 2021-05 Update: Yes I think this is true after putting all flux plates on same plot.
- it could be that top & bottom are flipped and also that what should be the top is actually flipped in sign?...need to compare to top.
- VATP
- Blip during station visit at 6/13/2018 21:00
Snow
Snow 2016-2017
Snow 2017-2018
Station History / Site Downloads / visits:
September 24 & 26 2018
- B Busey / Bolton / CAS
- memory problem on logger 9/24 but due to food poisoning just downloaded data.
- returned 9/26 and upgraded the OS to latest
- resent program & readdressed.
- I don't yet know the problem here? Error in CF card perhaps? In 2019 I will replace the CF card with another.
June 13 & 15 2018
- Station Maintenance @
- 6/13/2018 20:00 UTC
- 6/15/2018 20:00 UTC
- B Busey & N Wales
- fixed animal damage
- snow sensor knocked over 12/25/2017
- tipping bucket removed probably around then, too.
- fixed program bug
April 10 2016
- Temporary station built above flood plain. Station put in at end of first snow survey trip of Teller.
- At that point this was labeled the blue site (the blue electrical tape IDed this site in the logistics phase).
- Site established around 4/10/2016
- AT/RH
- 4 component Radiation
- Surface water
April 21 - May 5 1 2016
- Station visited nearly daily during ablation trip
July 2016
- LC visited and downloaded data.
- Temporary station had fallen over (knocked by an animal).
August 12 - 22 2016
- LC & B Busey improve upon site making Teller Bottom site and splitting off the Teller Surface Water Station.
- Wind Speed / Direction added
- W
Instrumentation and Heights
- AT/RH @ 1.85m
- Vaisala HMP155
- https://www.campbellsci.com/hmp155a
- Temperature Range: -80 to +60 Celsius
- Temperature Accuracy: (0.226 - 0.0028 x temperature)°C (-80° to +20°C)
- Humidity Range: 0 to 100 % Relative Humidity
- Humidity Accuracy: ±(1.2 + 0.012 × reading) % RH (at -40° to -20°C); ±(1.0 + 0.008 × reading) % RH (at -20° to +40°C)
- WS/WD @ 3.74m
- RM Young 01503
- https://www.campbellsci.com/05103-l
- Range: 0 to 100 m/s
- Accuracy: +-0.3m/s
- Startup threshold: 1.0 m/s
- Wind Direction measurement band: 0 to 355 degrees
- Accuracy: +-3 degrees
- Snow Depth @ Tripod
- Campbell Scientific SR50A
- https://www.campbellsci.com/sr50a
- Resolution: 0.25mm
- Accuracy: +-1.0 cm
- Snow Depth @ Lump
- Campbell Scientific SR50A
- https://www.campbellsci.com/sr50a
- Resolution: 0.25mm
- Accuracy: +-1.0 cm
- Net Radiation @ 1.5m
- Kipp & Zonen CNR4
- https://www.campbellsci.com/cnr4
- Shortwave Measurement Range- 305 to 2800 nm
- Shortwave Uncertainty in total daily - < 5% (The uncertainty values are for a 95% confidence level.)
- Longwave Measurement Range - 4500 to 42,000 nm
- Longwave Uncertainty in total daily- < 10% (The uncertainty values are for a 95% confidence level.)
- Skin Temperature @ 1.9m:
- Apogee Instruments SI-111
- https://www.campbellsci.com/si-111
- Operating Range: -55 to +80 C
- Accuracy: ±0.2°C (-10° to +65°C) & ±0.5°C (-40° to +70°C)
- Field of View: 22° half angle
- Summer Precipitation
- Texas Instruments TE525MM Metric model
- https://www.campbellsci.com/te525mm-l
- Accuracy: 1.0% up to 50 mm/hr
- Soil Moisture
- Stevens Hydrasense II
- https://amarillo.nserl.purdue.edu/ceap/metadata/Stevens_Hydra_soil.pdf
- Range Dielectric Constant: 1 = Air to 78 = Distilled Water
- Accuracy Dielectric Constant: ±1.5% or 0.2 whichever is greater
- Soil Moisture Range: Completely Dry to completely saturated
- Soil Moisture Accuracy: ±0.03 water fraction by volume in typical soil
- Conductivity Range: 0.01 to 1.5 Siemens per meter
- Conductivity Accuracy: ±2.0% or 0.005 S/m whichever is greater
- Temperature Range: -10 to +65 Degrees Celsius
- Temperature Accuracy: ±0.1 Degrees Celsius
- Soil Heat Flux
- https://www.campbellsci.com/hfp01
- Sensitivity: 50 μV W-1 m-2 (nominal)
- Accuracy: Within -15% to +5% in most common soils (12 hour totals)
- Snow Temperature
- Thermistor - US Sensor PS302J2
- https://www.littelfuse.com/~/media/electronics/datasheets/leaded_thermistors/littelfuse_leaded_thermistors_interchangeable_thermistors_standard_precision_ps_datasheet.pdf.pdf
- Range: -80 to +75 Degrees Celsius
- Accuracy: ±0.1 Degrees Celsius
- Backup Air Temperature
- Thermistor - US Sensor PS302J2
- https://www.littelfuse.com/~/media/electronics/datasheets/leaded_thermistors/littelfuse_leaded_thermistors_interchangeable_thermistors_standard_precision_ps_datasheet.pdf.pdf
- Range: -80 to +75 Degrees Celsius
- Accuracy: ±0.1 Degrees Celsius
- Soil Temperature
- Thermistor - US Sensor PS103J2
- https://www.littelfuse.com/~/media/electronics/datasheets/leaded_thermistors/littelfuse_leaded_thermistors_interchangeable_thermistors_standard_precision_ps_datasheet.pdf.pdf
- Range: -80 to +75 Degrees Celsius
- Accuracy: ±0.1 Degrees Celsius
- Soil thermal conductivity
- East30 Sensors Thermal Conductivity
- Thermal Conductivity Accuracy: ±5% (Except at soil temperature range about -1.5 to 0.0 Degrees Celsius)
- https://www.east30sensors.com/thermalconductivity
- Temperature Accuracy: ±0.1 Degrees Celsius
- NDVI
- http://publications.metergroup.com/Integrator%20Guide/18310%20SRS-N%20Integrator%20Guide.pdf
- Lower Measurement Band: 650 nm ±2 nm peak wavelengths
- Upper Measurement Band: 810 nm ±2 nm peak wavelengths
- 36 degree field of view
- PRI
- http://publications.metergroup.com/Integrator%20Guide/18311%20SRS-P%20Integrator%20Guide.pdf
- Lower Measurement Band: 532 nm ±2 nm peak wavelengths
- Upper Measurement Band: 570 nm ±2 nm peak wavelengths
- 36 degree field of view