Line 5: Line 5:
 
=site logs=
 
=site logs=
  
 +
== 29 August 2007, Rob Gieck (entered by E. Youcha) ==
 +
* Weir is level but the screws were pulled loose from the first joint east of the stilling well and at the 3rd joint east of stilling well.  The section in between is jacking a lot.
  
 
== 28 August 2007, Rob Gieck (entered by E. Youcha) ==
 
== 28 August 2007, Rob Gieck (entered by E. Youcha) ==

Latest revision as of 09:35, 7 November 2007

Imnavait Creek Weir

site TODO list

  • record as-built wiring of soil sensors
  • Flex conduit as needed

site logs

29 August 2007, Rob Gieck (entered by E. Youcha)

  • Weir is level but the screws were pulled loose from the first joint east of the stilling well and at the 3rd joint east of stilling well. The section in between is jacking a lot.

28 August 2007, Rob Gieck (entered by E. Youcha)

  • took SR50 distances using cone method, center 131.5cm, E=128.4 cm, N=141.3, W=135, S=136.5

16 July 2007, Ken I.

weir chart

  • changed chart, 9:51 AKST
  • staff gauge 0.445
  • flow is just over the entire width of the weir (which looks level)

snow depth sensor

  • 140 cm to ground
  • vegetation growing to about 128 cm below sensor

mid-stream stilling well

  • changed chart
  • notes in other logbook...