Difference between revisions of "Ken 2005-2"
Jump to navigation
Jump to search
imported>Ken |
imported>Ken |
||
| Line 14: | Line 14: | ||
* p41, 18jul06, DBM1, (Ken, ?) | * p41, 18jul06, DBM1, (Ken, ?) | ||
* p46, 23aug06, schematic GWS thermister strings | * p46, 23aug06, schematic GWS thermister strings | ||
| − | + | GWS thermistor string: | |
| − | GWS thermistor string: | ||
| − | |||
cm tape | cm tape | ||
--- ---- | --- ---- | ||
| Line 32: | Line 30: | ||
150 BLK/BLU | 150 BLK/BLU | ||
| − | typical wiring sketch for thermistors to multiplexer: | + | typical wiring sketch for thermistors to multiplexer: |
| − | |||
4L -- common to 4H, 3L, 3H | 4L -- common to 4H, 3L, 3H | ||
4H -- bead | 4H -- bead | ||
| Line 40: | Line 37: | ||
3H -- bead | 3H -- bead | ||
| − | soil moisture sensors: | + | soil moisture sensors: |
| − | |||
10 cm RED SE9 | 10 cm RED SE9 | ||
20 cm BLU SE10 | 20 cm BLU SE10 | ||
| Line 52: | Line 48: | ||
* p56, 28aug06, DBM3, (Ken, Alex) | * p56, 28aug06, DBM3, (Ken, Alex) | ||
* p57, 28aug06, DBR3, (Ken, Alex) | * p57, 28aug06, DBR3, (Ken, Alex) | ||
| − | + | soil surface temp colors: | |
red-grn -- 6.6k | red-grn -- 6.6k | ||
blu-org -- 6.5k | blu-org -- 6.5k | ||
wht-blk -- 6.48k | wht-blk -- 6.48k | ||
| + | |||
* p58, 29aug06, Sagwon Hill, (Ken), radio checks, downloads from truck | * p58, 29aug06, Sagwon Hill, (Ken), radio checks, downloads from truck | ||
Latest revision as of 11:25, 7 September 2007
WERC field book, ken 2005-2
- p13, 8jun06, DFM1, (Ken, John G)
- p14, 8jun06, DFR1, (Ken, John)
- p15, 8jun06, DFM4, (Ken, John)
- p16, 10jun06, DFM1, (Ken, Doug)
- p18, 11jun06, DBM2, (Ken, Doug)
- p20, 12jun06, DBM6, (Ken, Alex K., Kevin)
- p22, 13jun06, DBM6, (Ken, Alex, Kevin)
- p25, 14jun06, DBM3, (Ken, Doug)
- p31, 15jul06, DBM1, (Ken, Doug)
- p32, 16jul06, DBM2, (Ken, Doug)
- p39, 17jul06, DBM2?, (Ken, ?)
- p41, 18jul06, DBM1, (Ken, ?)
- p46, 23aug06, schematic GWS thermister strings
GWS thermistor string:
cm tape
--- ----
0 BLK
5 BLU
10 BRN
15 GRY
20 GRN
40 ORG
60 RED
80 VIO
100 WHT
120 YEL
135 BLK/BLK
150 BLK/BLU
typical wiring sketch for thermistors to multiplexer:
4L -- common to 4H, 3L, 3H
4H -- bead
G
3L -- bead
3H -- bead
soil moisture sensors:
10 cm RED SE9
20 cm BLU SE10
40 cm GRY SE11
- p50, 25aug06, trip plan & site visits summary
- p53, 26aug06, DFM1, (Ken, Alex, Rob)
- p54, 27aug06, DBM2, (Ken, Alex, Rob)
- p55, 27aug06, DBR2, (Ken, Alex, Rob)
- p56, 28aug06, DBM3, (Ken, Alex)
- p57, 28aug06, DBR3, (Ken, Alex)
soil surface temp colors: red-grn -- 6.6k blu-org -- 6.5k wht-blk -- 6.48k
- p58, 29aug06, Sagwon Hill, (Ken), radio checks, downloads from truck