===Post Trip Notes====
 +
* Need proper diameter screw for securing nuc to wall
 +
* took a bunch of photos that need to be uploaded to dropbox and then I can update the google presentation.
 +
* HMP155s
 +
** D site and C site lower units were too corroded to replace so only did tips.
 +
** replaced top C HMP155 with a new one.
 +
** also replaced a tip and HMP155 at B
 +
** replaced A lower HMP155 and moved it to the upper position. 
 +
** Almost all S/N from units out there were sun bleached off.
 +
** Leveled all radiometer Domes and swapped out desiccant.
 +
** leveled A & C precip buckets (C was already level, A was off just a bit)
 +
** Replaced all SR50A Transducers (2 @A, 2 @ B, 3 @ C, 1 @ D)
 +
*** emailed CSI asking the dimensions for replacement screws for the SR50A
 +
* Shed computer is still offline. I swapped the summper RPi back in place but that didn't get me anywhere.  Observing, it looked a little like the network connection is slow to be established and so the computers just remain offline.  but that's kind of what I saw with my laptop.  I connected... got an IP address slowly and then the internet didn't work until a bit after that.  For whatever reason. 
 +
** So, since I couldn't get anything to work I brought the NUC out with me.  When I arrived and the first couple of power restarts the LED code was OS upgrade in progress.  I'm not sure what that was about.  A couple potential alternatives might be read only OS / ram drive for logging as needed (though perhaps risky). 
 +
* didn't touch any of the WS sensors.
 +
* downloaded data from all sites and there was data dating to 2016-2017 so good news as it seems the cardout instructions are working properly on all four loggers.
 +
* noticed the MD485 connection to grid site was loose / perhaps off so I screwed it back in but didn't test link.
 +
* the main good news is that since the cardout is working properly the real-time connection is less important.  Just disappointing.
 +
* made good use of the ladder from the flux tower to get the 3.5m sensors fixed
 +
* replaced the antenna at the C site so hopefully will improve radio link.
 +
* For the record:
 +
** Flew in on evening flight.
 +
** next morning filled two daypacks for the day's work.
 +
** got breakfast
 +
** met up with UIC for safety training.
 +
** started walking to site around 10am.
 +
** Got back to truck at the end of the day around... 4:45 I think it was
 +
** A slightly less intense trip would be fly in on the morning flight, get the safety training out of the way and then still leave on the evening flight.  Something like that schedule would allow for more miserable weather as we had fantastic weather (clear / sunny & quite windy).
 +
** safety training done the day before would also allow for an earlier start.
 +
 +
===Fairbanks todo===
 +
* pull out necessary tools
 +
* pack gear
 +
* pack daypack
 +
* charge drill
 +
* assemble food & drink
 +
 
===Important Times===
 
===Important Times===
 
* Flight: Alaska 192 Departs: Fairbanks (FAI) on Mon, '''Oct 1 at 11:00 am'''
 
* Flight: Alaska 192 Departs: Fairbanks (FAI) on Mon, '''Oct 1 at 11:00 am'''
Line 4: Line 42:
 
* Flight: Alaska 50 Departs: Barrow (BRW) on Tue, '''Oct 2 at 7:09 pm'''
 
* Flight: Alaska 50 Departs: Barrow (BRW) on Tue, '''Oct 2 at 7:09 pm'''
  
===To Do===
+
===Utq To Do===
 +
====General====
 +
* Bring electrical tape to re-cover HMP155 sensor ends for moisture protection
 +
* Bring grease / anti corrosion compound for electrical connections
 +
* Bring SR50A transducers
 +
* Bring Net Radiometer Desiccant
  
 +
====Site A====
 +
* Replace 2x SR50A transducers
 +
* Replace HMP155 failed (3.5m)
 +
* Replace tip on HMP155 (1.4m)
 +
* Level Tipping Bucket
 +
* Level Radiometer
 +
* Change Radiometer Desiccant
 +
* Polish Radiometer domes
  
* Intensive Site A HMP155 failed (3.5m)
+
====Site B====
 +
* Replace 2x SR50A transducers
 
* Intensive Site B HMP155 failed (1.4m)
 
* Intensive Site B HMP155 failed (1.4m)
 +
* Level Tipping Bucket
 +
* Level Radiometer
 +
* Change Radiometer Desiccant
 +
* Polish Radiometer domes
 +
 +
====Site C====
 +
* Replace 3x SR50A transducers
 
* Intensive Site C HMP155 failed
 
* Intensive Site C HMP155 failed
* Have 2-3 additional HMP155 membrane tips
+
* Level Tipping Bucket
** bringing a bit of electrical tape to seal these things up after sensor replacement
+
* Level Radiometer
 +
* Change Radiometer Desiccant
 +
* Polish Radiometer domes
 +
* Check connection to soil moisture grid logger MD485 relay
 +
* Move antenna outside of box and if needed, use fish tape for this step
 +
** have also included some extra duct seal if needed for re-sealing of box
 +
 
 +
====Site D====
 +
* Replace 1x SR50A transducers
 +
* Replace tip on HMP155 (1.4m)
 +
* Level Radiometer
 +
* Change Radiometer Desiccant
 +
* Polish Radiometer domes
 +
 
 +
====BEO Control Shed====
 
* need to replace the network cable running from the computer to the network switch.  It cuts out with minimal bumping...
 
* need to replace the network cable running from the computer to the network switch.  It cuts out with minimal bumping...
 
** I think I almost need to connect the computer to a screen to see where the hang up is if it indeed turned on so I'll bring my light keyboard/mouse and an HDMI to DVI cord.
 
** I think I almost need to connect the computer to a screen to see where the hang up is if it indeed turned on so I'll bring my light keyboard/mouse and an HDMI to DVI cord.
* Site A SR50A transducers have failed
 
* Check level of tipping buckets
 
* Check level of radiometers
 
** replace radiometer desiccant
 
** polish radiometer domes
 
* some subsurface items are beginning to fail.
 
 
* label the computer
 
* label the computer
 
* bring up the nuc plate and wood screws and other screw packet to mount nuc to wall
 
* bring up the nuc plate and wood screws and other screw packet to mount nuc to wall

Latest revision as of 18:21, 3 October 2018

Post Trip Notes=

  • Need proper diameter screw for securing nuc to wall
  • took a bunch of photos that need to be uploaded to dropbox and then I can update the google presentation.
  • HMP155s
    • D site and C site lower units were too corroded to replace so only did tips.
    • replaced top C HMP155 with a new one.
    • also replaced a tip and HMP155 at B
    • replaced A lower HMP155 and moved it to the upper position.
    • Almost all S/N from units out there were sun bleached off.
    • Leveled all radiometer Domes and swapped out desiccant.
    • leveled A & C precip buckets (C was already level, A was off just a bit)
    • Replaced all SR50A Transducers (2 @A, 2 @ B, 3 @ C, 1 @ D)
      • emailed CSI asking the dimensions for replacement screws for the SR50A
  • Shed computer is still offline. I swapped the summper RPi back in place but that didn't get me anywhere. Observing, it looked a little like the network connection is slow to be established and so the computers just remain offline. but that's kind of what I saw with my laptop. I connected... got an IP address slowly and then the internet didn't work until a bit after that. For whatever reason.
    • So, since I couldn't get anything to work I brought the NUC out with me. When I arrived and the first couple of power restarts the LED code was OS upgrade in progress. I'm not sure what that was about. A couple potential alternatives might be read only OS / ram drive for logging as needed (though perhaps risky).
  • didn't touch any of the WS sensors.
  • downloaded data from all sites and there was data dating to 2016-2017 so good news as it seems the cardout instructions are working properly on all four loggers.
  • noticed the MD485 connection to grid site was loose / perhaps off so I screwed it back in but didn't test link.
  • the main good news is that since the cardout is working properly the real-time connection is less important. Just disappointing.
  • made good use of the ladder from the flux tower to get the 3.5m sensors fixed
  • replaced the antenna at the C site so hopefully will improve radio link.
  • For the record:
    • Flew in on evening flight.
    • next morning filled two daypacks for the day's work.
    • got breakfast
    • met up with UIC for safety training.
    • started walking to site around 10am.
    • Got back to truck at the end of the day around... 4:45 I think it was
    • A slightly less intense trip would be fly in on the morning flight, get the safety training out of the way and then still leave on the evening flight. Something like that schedule would allow for more miserable weather as we had fantastic weather (clear / sunny & quite windy).
    • safety training done the day before would also allow for an earlier start.

Fairbanks todo

  • pull out necessary tools
  • pack gear
  • pack daypack
  • charge drill
  • assemble food & drink

Important Times

  • Flight: Alaska 192 Departs: Fairbanks (FAI) on Mon, Oct 1 at 11:00 am
  • Sunrise: Oct 2 at 8:50 AM
  • Flight: Alaska 50 Departs: Barrow (BRW) on Tue, Oct 2 at 7:09 pm

Utq To Do

General

  • Bring electrical tape to re-cover HMP155 sensor ends for moisture protection
  • Bring grease / anti corrosion compound for electrical connections
  • Bring SR50A transducers
  • Bring Net Radiometer Desiccant

Site A

  • Replace 2x SR50A transducers
  • Replace HMP155 failed (3.5m)
  • Replace tip on HMP155 (1.4m)
  • Level Tipping Bucket
  • Level Radiometer
  • Change Radiometer Desiccant
  • Polish Radiometer domes

Site B

  • Replace 2x SR50A transducers
  • Intensive Site B HMP155 failed (1.4m)
  • Level Tipping Bucket
  • Level Radiometer
  • Change Radiometer Desiccant
  • Polish Radiometer domes

Site C

  • Replace 3x SR50A transducers
  • Intensive Site C HMP155 failed
  • Level Tipping Bucket
  • Level Radiometer
  • Change Radiometer Desiccant
  • Polish Radiometer domes
  • Check connection to soil moisture grid logger MD485 relay
  • Move antenna outside of box and if needed, use fish tape for this step
    • have also included some extra duct seal if needed for re-sealing of box

Site D

  • Replace 1x SR50A transducers
  • Replace tip on HMP155 (1.4m)
  • Level Radiometer
  • Change Radiometer Desiccant
  • Polish Radiometer domes

BEO Control Shed

  • need to replace the network cable running from the computer to the network switch. It cuts out with minimal bumping...
    • I think I almost need to connect the computer to a screen to see where the hang up is if it indeed turned on so I'll bring my light keyboard/mouse and an HDMI to DVI cord.
  • label the computer
  • bring up the nuc plate and wood screws and other screw packet to mount nuc to wall
  • troubleshoot the network connection in control shed.
  • take new pictures of inside control shed

To Bring

  • Tools
    • CSI Phillips for opening CNR4 radiometers and SR50A
    • Tap & Die in case any more radiometer screws strip
    • torpedo level for tipping bucket level
    • 5/16" screw driver for tipping bucket level
    • electrical tape for HMP155 replacement
    • Antenna & coax for C site to get antenna outside of the box. (two different antennas will decide on which up in Utqiagvik)
    • Drill & battery for potential tap & die stuff


On Site

  • Should be a ladder at the NGEE Flux tower for use replacing 3.5m instruments