+ | ==Trip Notes== | ||
+ | Anti corrosion goo saved the day here. No screws stripped on this visit. Everything easy to swap. Definite best case scenario after a three year gap between visits. | ||
+ | * @ Site A | ||
+ | ** Replaced all AT/RH and 014A sensors with new / recalibrated units | ||
+ | *** Lower 014A had bent cups but both should be reading NAN until visit. | ||
+ | ** replaced both snow transducers | ||
+ | ** leveled CNR4 and replaced desiccant | ||
+ | ** leveled tipping bucket | ||
+ | ** site back to 100%. | ||
+ | * @ Site B | ||
+ | ** Replaced all AT/RH and 014A sensors with new / recalibrated units | ||
+ | ** replaced both snow transducers | ||
+ | *** Tripod SR50A not reading. I looked over the wires and the data and I think this must have been an issue in 2019, too as all the wiring looks ok. So I vote internal corrosion or something else. | ||
+ | ** leveled CNR4 and replaced desiccant | ||
+ | * @ Site C | ||
+ | ** Replaced both 014A WS | ||
+ | ** Only replaced upper HMP155. The lower one is still working and and the sensor cable was corroded onto the sensor. I think with a skinny wrench (and here I am thinking probably a metric bike tool would be the hot ticket) they could be disconnected but since it was still working, shoulder shrug emoji, just left it as-is. | ||
+ | ** Tipping bucket still level and so didn't fuss with it. | ||
+ | * @ Site D | ||
+ | ** Replaced the 014A WS | ||
+ | ** Did not replace HMP155 as it is still working. | ||
+ | * @ BEO Control Shed | ||
+ | ** Redeployed the computer | ||
+ | ** it worked right off and data downloads resumed. | ||
+ | ** now using an internal IP address and pushing data to ocotal | ||
+ | ** SSH connection to monitors is broken by monitors firewall so I will need to look into current IP. | ||
+ | |||
==Activities== | ==Activities== | ||
+ | * I listed things working and broken below but I also brought enough instruments to completely replace: | ||
+ | ** All [[Snow Transducer Replacement|snow transducers]] | ||
+ | |||
+ | ** All [[HMP155 Sensor Replacement|AT/RH]] | ||
+ | ** All [[MetOne 014A Anemometer Replacement |WS]] | ||
+ | ** All [[CNR4 Desiccant Replacement |CNR4 desiccant]] | ||
==To Bring== | ==To Bring== | ||
Line 11: | Line 44: | ||
* Computer | * Computer | ||
− | == | + | ==Data Refresher== |
+ | ===These notes as of May 2021 download....=== | ||
+ | * Site A Notes suggest nothing major wrong | ||
+ | ** 3.5m at/rh might be in need of replacement | ||
+ | ** planning to replace both ws | ||
+ | ** replace desiccant in CNR4 | ||
+ | ** Level tipping bucket | ||
+ | * Site B Notes | ||
+ | ** Replace lower AT/RH | ||
+ | ** replace both WS | ||
+ | ** replace desiccant in CNR4 | ||
+ | ** Level tipping bucket (could ignore since I don't really use this one after a data review) | ||
+ | * Site C Notes | ||
+ | ** 3.5m at/rh might be in need of replacement | ||
+ | ** planning to replace both ws | ||
+ | ** replace desiccant in CNR4 | ||
+ | ** Level tipping bucket | ||
+ | * Site D Notes | ||
+ | ** planning to replace ws | ||
+ | ** replace desiccant in CNR4 |
Latest revision as of 10:03, 23 September 2022
Contents
Trip Notes
Anti corrosion goo saved the day here. No screws stripped on this visit. Everything easy to swap. Definite best case scenario after a three year gap between visits.
- @ Site A
- Replaced all AT/RH and 014A sensors with new / recalibrated units
- Lower 014A had bent cups but both should be reading NAN until visit.
- replaced both snow transducers
- leveled CNR4 and replaced desiccant
- leveled tipping bucket
- site back to 100%.
- Replaced all AT/RH and 014A sensors with new / recalibrated units
- @ Site B
- Replaced all AT/RH and 014A sensors with new / recalibrated units
- replaced both snow transducers
- Tripod SR50A not reading. I looked over the wires and the data and I think this must have been an issue in 2019, too as all the wiring looks ok. So I vote internal corrosion or something else.
- leveled CNR4 and replaced desiccant
- @ Site C
- Replaced both 014A WS
- Only replaced upper HMP155. The lower one is still working and and the sensor cable was corroded onto the sensor. I think with a skinny wrench (and here I am thinking probably a metric bike tool would be the hot ticket) they could be disconnected but since it was still working, shoulder shrug emoji, just left it as-is.
- Tipping bucket still level and so didn't fuss with it.
- @ Site D
- Replaced the 014A WS
- Did not replace HMP155 as it is still working.
- @ BEO Control Shed
- Redeployed the computer
- it worked right off and data downloads resumed.
- now using an internal IP address and pushing data to ocotal
- SSH connection to monitors is broken by monitors firewall so I will need to look into current IP.
Activities
- I listed things working and broken below but I also brought enough instruments to completely replace:
- All snow transducers
- All AT/RH
- All WS
- All CNR4 desiccant
To Bring
- Radiometer Desiccant
- SR50A transducers
- Anemometers
- Tap & Die set for radiometers
- Anti Corrosion Goo
- Toughbook
- Toolbags
- Computer
Data Refresher
These notes as of May 2021 download....
- Site A Notes suggest nothing major wrong
- 3.5m at/rh might be in need of replacement
- planning to replace both ws
- replace desiccant in CNR4
- Level tipping bucket
- Site B Notes
- Replace lower AT/RH
- replace both WS
- replace desiccant in CNR4
- Level tipping bucket (could ignore since I don't really use this one after a data review)
- Site C Notes
- 3.5m at/rh might be in need of replacement
- planning to replace both ws
- replace desiccant in CNR4
- Level tipping bucket
- Site D Notes
- planning to replace ws
- replace desiccant in CNR4