Difference between revisions of "NGEE Barrow 2013 Site Install Trip"
		
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
		
		
		
		
		
	
| Line 53: | Line 53: | ||
| − | + | ===Rough on-site todo===  | |
# Copy wiring of Grid Site  | # Copy wiring of Grid Site  | ||
# Transfer wires to new multiplexer & Logger  | # Transfer wires to new multiplexer & Logger  | ||
| Line 59: | Line 59: | ||
# Measure Heater Resistances for all thermal conductivity probes  | # Measure Heater Resistances for all thermal conductivity probes  | ||
# Look to see if the C site pit 2 thermal conductivity sensors could be connected to a lower instrument enclosure.  | # Look to see if the C site pit 2 thermal conductivity sensors could be connected to a lower instrument enclosure.  | ||
| + | # configure C as pakbus router for grid   | ||
| + | ## http://www.campbellsci.com/forum/messages.cfm?threadid=6E4ABAA0-81A1-4158-B850230D8A56A2EF  | ||
| + | # armor and run rs485 line between C and grid  | ||
Revision as of 21:52, 4 May 2013
Contents
May 2013 Trip
Purpose:
- Rewire Grid Site station with CR1000 & new multiplexers
 - Setup MD485s to get Grid online
 - reconfigure Site C CR1000 for act as a pakbus router
 - Snow Surveys
 - Any other prep that's possible for the June trip
 - Bring back shotgun
 - slather anticorrosion goo on all 12V/G points?
 - Record Thermal Conductivity Heater Resistance using a high-accuracy ohmmeter
 - Swap out SR50A
 
Shipping
- None
 
To Purchase
- Anti-Corrosion Goo
 - Ziplocs
 - In Barrow:
- Butane
 
 - Food?
 
Pre-trip to do
- Read up on CR1000 Pakbus Routing
 - Pack
 
Stuff to bring
- Adirondack Tube
 - Scale
 - Thaw Probe
 - Ziplocs
 - GPS
 - 4 Precision Resistors for new logger
 - High Precision Voltmeter
 
Technical Gear
- Shotgun -- in Barrow already
 - Keypads
 - fish tape
 - Tool Bags
 - Computer & (packed) SC32B
 - Climbing harness
 - Serial Cables & spares
 - Sawzall
 - drill
 
Food to bring out
- Optional
 
Probable Luggage
- Bob Personal Actionpacker [Bob #1]
 - Work Actionpacker #1 [Bob #2]
 
Rough on-site todo
- Copy wiring of Grid Site
 - Transfer wires to new multiplexer & Logger
 - Snowsurveys
 - Measure Heater Resistances for all thermal conductivity probes
 - Look to see if the C site pit 2 thermal conductivity sensors could be connected to a lower instrument enclosure.
 - configure C as pakbus router for grid
 - armor and run rs485 line between C and grid