Difference between revisions of "Oliktok summer 2017 trip"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
+ | ===for telayna=== | ||
*replace sr50a transducers | *replace sr50a transducers | ||
**1)unscrew sensor from mount | **1)unscrew sensor from mount | ||
Line 10: | Line 11: | ||
**8)replace the sensor on the mount and screw in the cable (which is notched) | **8)replace the sensor on the mount and screw in the cable (which is notched) | ||
− | |||
− | |||
*put up temperature sensor | *put up temperature sensor | ||
+ | **mount it as close to SR50a quadpod as possible | ||
+ | **wiring to CR1000 logger | ||
+ | **Red -- SW-12 | ||
+ | **yellow -- SE11 | ||
+ | **blue -- SE12 | ||
+ | **clear -- AG | ||
+ | **black -- AG | ||
+ | **white -- AG | ||
+ | |||
**cable housing | **cable housing | ||
*plastic cable covers for all cables entering into the logger? | *plastic cable covers for all cables entering into the logger? | ||
− | + | ||
*CFM100 | *CFM100 | ||
**1)unplug power from logger | **1)unplug power from logger | ||
Line 21: | Line 29: | ||
**3)re-plug power to the logger | **3)re-plug power to the logger | ||
**4) | **4) | ||
+ | *level geonor | ||
+ | |||
+ | *tools i'm sending you with | ||
+ | **7/16 nut driver | ||
+ | **small flathead screw driver | ||
+ | **small Philips screw driver | ||
+ | ====other=== | ||
+ | *antifreeze | ||
+ | *snip vegetation underneath |
Revision as of 12:38, 7 September 2017
for telayna
- replace sr50a transducers
- 1)unscrew sensor from mount
- 2)unscrew cable from sensor
- 3)unscrew all little screws holding the transducer to the sensor body (use the frisbee to work so you don't lose the little screws)
- 4)unclip the wires of the old transducer, remove the O ring
- 5)place desiccant in the new transducer
- 5)place the new O ring on the sensor body and clip the new transducer wire
- 6)line up the notch of the new transducer on the sensor body
- 7)screw in all the little screws
- 8)replace the sensor on the mount and screw in the cable (which is notched)
- put up temperature sensor
- mount it as close to SR50a quadpod as possible
- wiring to CR1000 logger
- Red -- SW-12
- yellow -- SE11
- blue -- SE12
- clear -- AG
- black -- AG
- white -- AG
- cable housing
- plastic cable covers for all cables entering into the logger?
- CFM100
- 1)unplug power from logger
- 2)plug and screw in the CFM100
- 3)re-plug power to the logger
- 4)
- level geonor
- tools i'm sending you with
- 7/16 nut driver
- small flathead screw driver
- small Philips screw driver
=other
- antifreeze
- snip vegetation underneath