===Instrumentation and Heights===
 +
* Barometric Air Pressure
 +
** Vaisala PTB110
 
* AT/RH @ 1.5m, 3.0m
 
* AT/RH @ 1.5m, 3.0m
 
** Rotronic HygroClip2 HC2A
 
** Rotronic HygroClip2 HC2A
Line 35: Line 37:
  
 
* Skin Temperature @ 1.5m:  
 
* Skin Temperature @ 1.5m:  
** Apogee Instruments SI-111  
+
** Apogee Instruments SI-111
  
 
===Data Downloads===
 
===Data Downloads===

Revision as of 10:56, 2 February 2021

History

  • Site installation 9/21 and 9/24 2018.
  • Final initial visit on 9/26/18
  • Pictures are filed in "2018 Work Nome September 2018" including pictures of fieldbook notes.
  • Site visit 2019-06-10
  • Site Visit 2019-06-16
  • Site Visit 2019-09-19

Instrumentation and Heights

  • Barometric Air Pressure
    • Vaisala PTB110
  • AT/RH @ 1.5m, 3.0m
    • Rotronic HygroClip2 HC2A
  • WS/WD @ 1.5m, 3.0m
    • RM Young 01503 variant
  • Snow Depth @ 3.0m
    • Campbell Scientific SR50A
  • Net Radiation @ 1.5m
    • Kipp & Zonen CNR4
  • Soil Pit 1 = Dry
    • Campbell Scientific CS109 sensors
    • 1.5cm bgs
    • 10cm bgs
    • 20cm bgs
    • 40cm bgs
    • 80cm bgs
  • Soil Pit 2 = Wet
    • Campbell Scientific CS109 sensors
    • 5cm bgs
    • 10cm bgs
    • 40cm bgs
    • 80cm bgs
  • All season Precipitation:
    • Geonor Weighing Bucket
    • ... only powered for summer season
    • Drained in October 2020
  • Skin Temperature @ 1.5m:
    • Apogee Instruments SI-111

Data Downloads

  • Station turned on, first record:
    • 2018-09-24 22:00
  • 2019-06-10 21:30
  • 2019-09-26 23:30
  • 2020-10-30 21:00

Post Trip Notes

October 2020

  • All AT/RH Broken
  • Think about putting out a second datalogger co-located since the wiring is so set... or not... I should look into it...
    • ... in order to have a nonborked reference air temperature and reference tipping bucket.


June 2019

  • Tripod Mast Bent
  • CNR4 difficult to level
  • Could use a some help keeping lower anemometer from moving. Like maybe a couple pieces of unistrut to keep arm from wobbling
  • Need to replace lower AT/RH as it seems completely broken.
    • Rotronic HygroClip2 HC2A
    • Should look to see if they sell a better top cap for it more resistant to moisture
  • Need to get some SW12V adapter to turn AT/RH on/off and look at program / wiring for other things that could be turned off.
  • Left 2 guy wire anchors and 100' of guy wire at UAF Storage. Could bring out more anchors or unistrut / nails or something. Maybe pound unistrut into ground and then pin in place?
  • I thought Geonor and Solar Panel would require guying but both survived the winter while tripod mast didn't.
  • I think snow sensor maybe failed over the winter, too.
  • I was thinking a heavier gauge cable for solar panel might be appropriate, too.