Difference between revisions of "Teller CAS"

From IARC 207 Wiki
Jump to navigation Jump to search
Line 17: Line 17:
 
* Barometric Air Pressure
 
* Barometric Air Pressure
 
** Vaisala PTB110
 
** Vaisala PTB110
 +
** https://www.campbellsci.com/cs106
 +
** Range:  500 to 1100 hPa
 +
** Accuracy: +-1.5 hPa -40 to +60 C
 
* AT/RH @ 1.5m, 3.0m
 
* AT/RH @ 1.5m, 3.0m
 
** Rotronic HygroClip2 HC2A
 
** Rotronic HygroClip2 HC2A
 +
** https://www.campbellsci.com/hc2s3
 +
** -40 to +60 Celsius
 +
** =-0.1 C at 23 C
 +
** 0 to 100 % Relative Humidity
 +
** +-0.8% at 23C
 
* WS/WD @ 1.5m, 3.0m
 
* WS/WD @ 1.5m, 3.0m
** RM Young 01503 variant
+
** RM Young 01508
* Snow Depth @ 3.0m
+
** https://www.campbellsci.com/05108-45-l
 +
** Range: 0 to 100 m/s
 +
** Accuracy: +-0.3m/s
 +
** Startup threshold: 1.0 m/s
 +
** Wind Direction measurement band: 0 to 355 degrees
 +
** Accuracy: +-3 degrees
 +
* Snow Depth @ 3.0
 
** Campbell Scientific SR50A
 
** Campbell Scientific SR50A
 +
** https://www.campbellsci.com/sr50a
 +
** Resolution: 0.25mm
 +
** Accuracy: +-1.2 cm  (0.4% of 3.0 meter measurement range)
 
* Net Radiation @ 1.5m
 
* Net Radiation @ 1.5m
 
** Kipp & Zonen CNR4
 
** Kipp & Zonen CNR4
 +
** https://www.campbellsci.com/cnr4
 +
** Shortwave Measurement Range-  305 to 2800 nm
 +
** Shortwave Uncertainty in total daily -  < 5% (The uncertainty values are for a 95% confidence level.) 
 +
** Longwave Measurement Range -  4500 to 42,000 nm
 +
** Longwave Uncertainty in total daily-  < 10% (The uncertainty values are for a 95% confidence level.)
 
* Soil Pit 1 = Dry
 
* Soil Pit 1 = Dry
 
** Campbell Scientific CS109 sensors
 
** Campbell Scientific CS109 sensors
 +
*** https://www.campbellsci.com/109
 +
*** Range:  -50° to +70°C
 +
*** Tolerance:  ±0.2°C (over 0° to 70°C range)
 +
*** Interchangeability Error:  ±0.1°C (over 0° to 70°C range increasing to ±0.5°C at -50°C)
 
** 1.5cm bgs
 
** 1.5cm bgs
 
** 10cm bgs
 
** 10cm bgs
Line 34: Line 60:
 
* Soil Pit 2 = Wet
 
* Soil Pit 2 = Wet
 
** Campbell Scientific CS109 sensors
 
** Campbell Scientific CS109 sensors
 +
*** https://www.campbellsci.com/109
 +
*** Range:  -50° to +70°C
 +
*** Tolerance:  ±0.2°C (over 0° to 70°C range)
 +
*** Interchangeability Error:  ±0.1°C (over 0° to 70°C range increasing to ±0.5°C at -50°C)
 
** 5cm bgs
 
** 5cm bgs
 
** 10cm bgs
 
** 10cm bgs
Line 40: Line 70:
 
* All season Precipitation:  
 
* All season Precipitation:  
 
** Geonor Weighing Bucket
 
** Geonor Weighing Bucket
 +
** https://www.geonor.com/brochures/t-200b-series-all-weather.pdf
 +
** Collecting Area - 200 cm^2
 +
** Capacity - 1500 mm H2O (including antifreeze)
 +
** Sensitivity - 0.05mm
 +
** Accuracy - 0.1% FS
 
** ... only powered for summer season
 
** ... only powered for summer season
 
** Drained in October 2020
 
** Drained in October 2020
Line 45: Line 80:
 
* Skin Temperature @ 1.5m:  
 
* Skin Temperature @ 1.5m:  
 
** Apogee Instruments SI-111
 
** Apogee Instruments SI-111
 +
** https://www.campbellsci.com/si-111
 +
** Operating Range: -55 to +80 C
 +
** Accuracy: ±0.2°C (-10° to +65°C) & ±0.5°C (-40° to +70°C)
 +
** Field of View:  22° half angle
  
 
===Data Downloads===
 
===Data Downloads===

Revision as of 11:44, 2 March 2021

Location

  • N64* 58' 36.918", W166* 12' 32.67", 67 meters above sea level.
    • (Location from picture)

History

  • Site installation 9/21 and 9/24 2018.
  • Final initial visit on 9/26/18
  • Pictures are filed in "2018 Work Nome September 2018" including pictures of fieldbook notes.
  • Additional Site visits:
    • 2019-06-10
    • 2019-06-16
    • 2019-09-19
    • 2019-09-26
    • 2020-10-30

Instrumentation and Heights

  • Barometric Air Pressure
  • AT/RH @ 1.5m, 3.0m
  • WS/WD @ 1.5m, 3.0m
    • RM Young 01508
    • https://www.campbellsci.com/05108-45-l
    • Range: 0 to 100 m/s
    • Accuracy: +-0.3m/s
    • Startup threshold: 1.0 m/s
    • Wind Direction measurement band: 0 to 355 degrees
    • Accuracy: +-3 degrees
  • Snow Depth @ 3.0
  • Net Radiation @ 1.5m
    • Kipp & Zonen CNR4
    • https://www.campbellsci.com/cnr4
    • Shortwave Measurement Range- 305 to 2800 nm
    • Shortwave Uncertainty in total daily - < 5% (The uncertainty values are for a 95% confidence level.)
    • Longwave Measurement Range - 4500 to 42,000 nm
    • Longwave Uncertainty in total daily- < 10% (The uncertainty values are for a 95% confidence level.)
  • Soil Pit 1 = Dry
    • Campbell Scientific CS109 sensors
      • https://www.campbellsci.com/109
      • Range: -50° to +70°C
      • Tolerance: ±0.2°C (over 0° to 70°C range)
      • Interchangeability Error: ±0.1°C (over 0° to 70°C range increasing to ±0.5°C at -50°C)
    • 1.5cm bgs
    • 10cm bgs
    • 20cm bgs
    • 40cm bgs
    • 80cm bgs
  • Soil Pit 2 = Wet
    • Campbell Scientific CS109 sensors
      • https://www.campbellsci.com/109
      • Range: -50° to +70°C
      • Tolerance: ±0.2°C (over 0° to 70°C range)
      • Interchangeability Error: ±0.1°C (over 0° to 70°C range increasing to ±0.5°C at -50°C)
    • 5cm bgs
    • 10cm bgs
    • 40cm bgs
    • 80cm bgs
  • All season Precipitation:
  • Skin Temperature @ 1.5m:
    • Apogee Instruments SI-111
    • https://www.campbellsci.com/si-111
    • Operating Range: -55 to +80 C
    • Accuracy: ±0.2°C (-10° to +65°C) & ±0.5°C (-40° to +70°C)
    • Field of View: 22° half angle

Data Downloads

  • Station turned on, first record:
    • 2018-09-24 22:00
  • 2019-06-10 21:30
  • 2019-09-26 23:30
  • 2020-10-30 21:00

Post Trip Notes

October 2020

  • All AT/RH Broken
  • Think about putting out a second datalogger co-located since the wiring is so set... or not... I should look into it...
    • ... in order to have a nonborked reference air temperature and reference tipping bucket.


June 2019

  • Tripod Mast Bent
  • CNR4 difficult to level
  • Could use a some help keeping lower anemometer from moving. Like maybe a couple pieces of unistrut to keep arm from wobbling
  • Need to replace lower AT/RH as it seems completely broken.
    • Rotronic HygroClip2 HC2A
    • Should look to see if they sell a better top cap for it more resistant to moisture
  • Need to get some SW12V adapter to turn AT/RH on/off and look at program / wiring for other things that could be turned off.
  • Left 2 guy wire anchors and 100' of guy wire at UAF Storage. Could bring out more anchors or unistrut / nails or something. Maybe pound unistrut into ground and then pin in place?
  • I thought Geonor and Solar Panel would require guying but both survived the winter while tripod mast didn't.
  • I think snow sensor maybe failed over the winter, too.
  • I was thinking a heavier gauge cable for solar panel might be appropriate, too.

Data Notes

Most Recent QA : 2021-02-11

Barometric Pressure

  • All Good
  • NAN data is due to low battery voltage

1.5 meter Air Temperature / Relative Humidity / Vapor Pressure

  • Sensor Fails over 2018-2019 winter due to moisture.
  • 2019-01-03 23:00 UTC

3.0 meter Air Temperature / Relative Humidity / Vapor Pressure

  • NAN data in 2019 Winter is due to low battery voltage
  • Without site visit hard to say why sensor goes dead on 2019-09-19 21:00
    • Loose wire?
    • the timing...

1.5 meter Anemometer

  • NAN data in Winter is due to low battery voltage

3.0 meter Anemometer

  • NAN data in Winter is due to low battery voltage

Precipitation

  • Disconnected in winter to reduce battery load.

Radiation

  • Albedo
    • Blip at 2018-11-20 3:30 to delete
    • need to limit to 0. to 1.

Soil Pit 1

  • Winter data gaps and NANs due to low battery voltage
  • Sensor 5 dies 2020-05-16 22:00
  • Sensor 3 dies 2020-05-16 22:00
  • Sensor 2 dies 2020-06-01 10:30
  • Sensor 4 dies 2020-06-01 10:30

Soil Pit 2

  • Winter data gaps and NANs due to low battery voltage

Snow

  • Transducer fails in January 2019.