Difference between revisions of "SS To Do Next Visit"

From IARC 207 Wiki
Jump to navigation Jump to search
Line 12: Line 12:
  
 
===2021===
 
===2021===
 +
* Bring out a gender changer for null modem plus a serial cable or two.
 
* Turn MD485 & NL201 for original data loggers into a NL100 w/ RS485 output.
 
* Turn MD485 & NL201 for original data loggers into a NL100 w/ RS485 output.
 
* Presentation outlining all Electrical plug ins and what is plugged into them.
 
* Presentation outlining all Electrical plug ins and what is plugged into them.

Revision as of 13:30, 31 July 2021

Sensor Review Page

Calibrations Swaps 2021

  • Forest Floor RS485 HMP155:
    • 7/29/21 Removed P3520500
    • Replaced with G4940001

Publications List

Sensor Refresh Budget

2021

  • Bring out a gender changer for null modem plus a serial cable or two.
  • Turn MD485 & NL201 for original data loggers into a NL100 w/ RS485 output.
  • Presentation outlining all Electrical plug ins and what is plugged into them.
  • XX Updated the network so it will work all of the time with or without LAN.
  • Need to update Licor Software
    • Update the windows, too?
  • Identify power needs
    • Submitted a PR for the power monitor.
  • Map out all network devices
    • Shoud grab pictures too.
  • Found alternate location near gate for SWE sensor.
  • Update Kathe on what is out here including estimated costs
  • Bring an HDMI splitter so both laptops can share the screen.
  • XX bring out the third small router so that the networking is more resilient.
  • build a tripod for the cameras?
  • Pick up all thread stock that will fit inside the large thimbles I have.
  • XX 6/3 Tower Top Radiometer bracket needs two more screws... old ones sheared off.
  • need to bring out a 1/2 inch nut for one anchor. 5/16" diameter... For North side
  • XX Location for SWE sensor
    • 6/3/2021: Snow pillow spot has 4-5m diameter space.
  • XX Make sure we can make the two tripods.
    • XX Yes
  • Check 6m AT/RH wiring.
    • I think we replaced it in March 2021 but it is still acting up so likely to be a cabling issue again.
    • have a cable just need to solder into a single piece. (where did this cable go...)
  • Send away anemometers
  • send away HMP155s
  • check calibration budget
  • XX try to buy CFM100s for soil and met loggers
  • XX Redo the forests floor AT/RH bracket.
  • complete inventory of gear in the office
  • XX copy down again the pakbus IDs to the wiki here...

Program Change

  • XX change ss_soil soil moisture to period averaging method to reduce overranging
  • XX add leaf wetness sensor to geonor again?
  • XX change sdi12 instruction for ss_ff_rad snow to output quality number... looks to be zero.
  • Check ss_soil_2 datapro config for soil temp 4 which shows good data while connected to station but nan on webpage.

May 2021 Datapro remainder Items

  • ss_geonor -- need to add charger key file etc
  • ss_soil_2 -- need to add sm_profile.dat and snow.dat to automated processing.
  • ss_ff_rad -- need to add snow to automated processing.

To Purchase

  • For SWE tripods:
    • 1 Inch Schedule 40 pipe, 10ft, 6pcs (leg / leg brace)
    • 1.5 inch schedule 40 pipe, 10 ft, 2 pcs (mast)
    • phenocam parts... 2" pvc maybe plus rubber gasket and what else?

2019

    • bring out MD485 to tie in to network out there

May 2019

  • check sr50a #2 maybe not working according to data.

2018

Fall List

  • Photograph tag & equipment for:
    • LICOR units (tower & forest)
      • Property Tag 36113 (I think this may be Y Kim)
      • Property Tag 36114 (I think this may be Y Kim)
    • 3 CR1000s
      • Property Tag 36104
      • Property Tag 36106
      • Property Tag 36117
  • Might add a SR50A to the soil pit
  • might add a SI111 to the soil pit
  • might add a UPS for the heat flux logger system in case there are power problems
    • the network switch connecting the toughbook to the LI7200 and the LI7200 to the fluxprocessor
  • Need to find out OS version of tower wind master pro
  • need to remove battery from sky cam laptop
  • bring out NL100/200.
  • error message associated with heat flux memory card... replace memory card.
  • order a LiCor network cable for forest floor.

Summer List

Ss soil has room on c5 for sdi12 rest or sr50a are on c3, c4 is open for other stuff.

  • C5 -- SDI12 ID 8 = Shed
  • C7 -- SDI12 ID 9 = Forest Floor Radiation Stand

Just moved cs616 to 5v to see if that does anything. Need to confirm this doesn't mess up and create noise in signals.

  • Replace SR50A transducers
  • Dig second pit for soil instruments
  • clean up outdoor power cords
  • waterproof a bit some of the tower blowers (might be as easy as more cable ties / tape to keep the white box deals right side up.
  • I brought out a collection of one and two hole deals for securing loose cabling here and there in and out of the shed. That could be sorted out.
  • connect those shop power strips and get one more for inside?
  • buy and add more PAR top and bottom (4x and matching hardware)
  • add another tipping bucket.
  • bring solder out for ff atrh blower and electrical goo