Difference between revisions of "K3 Mauze"

From IARC 207 Wiki
Jump to navigation Jump to search
Line 35: Line 35:
  
 
=== Site Log / Visits ===
 
=== Site Log / Visits ===
 +
6/15/2008 Visit:
 +
1m HMP45C Z1730125
 +
3m HMP45C Z1730128
 +
Net Radiometer Q99012 Installed 6/15/2008
 +
Positive Coefficient: 8.97 W/m^2/mV, Negative Coefficient: 10.90 W/m^2/mV

Revision as of 16:22, 20 June 2008

June 2008 Trip

  • Download Data
  • Send new program (snow sensor)
  • add net radiometer
  • Site could use a new battery

Site Data

Current Data Headers
Raw Data Archive
Processed Data Archive

Problem Sensors (as of June 2008)

  • Met look good except precip.

Replace Batteries: 400px
Check Precip Bucket Wiring: 400px
Post Script (June 2008) the Pulse port for the precip bucket had gone bad. So, bucket was re-wired into a control port (after replacing the cable that we then learned was still intact).

New snow sensor looks great: 400px
Check Soil Temperature 55 cm bgs (9th thermistor).

Sensors Installed at this Station

  • 1m HMP45C Air Temperature / Relative Humidity
  • 3m HMP45C Air Temperature / Relative Humidity
  • 3m Wind Speed / Wind Direction
  • Summer Precipitation
  • Net Radiation (summer only)
  • Campbell Scientific SR50A Sonic Snow Depth Sensor (Added 9/2007)

Site To Do List

Site Log / Visits

6/15/2008 Visit:

1m HMP45C Z1730125
3m HMP45C Z1730128
Net Radiometer Q99012 Installed 6/15/2008
Positive Coefficient: 8.97 W/m^2/mV, Negative Coefficient: 10.90 W/m^2/mV