− | == | + | ==To Bring from Fairbanks== |
+ | * Cabling to extend thermocouple temperature profile from old enclosure to new enclosure. | ||
+ | * shovels for digging out buried cabling | ||
+ | * extension cord | ||
+ | * cable splicing tools | ||
+ | ** soldering iron | ||
+ | ** butane | ||
+ | ** propane torch | ||
+ | ** solder | ||
+ | ** heat shrink | ||
+ | * extra cabling | ||
+ | * Toolbags | ||
+ | * Extra data logger (CR1000, for any instruments that aren't transferred to the new logger on this trip and or don't reach... completely just a back up item) | ||
+ | * small actionpacker | ||
+ | * sled | ||
+ | * Climbing harness | ||
− | New tower w/ enclosure & guy wires | + | == Current Equipment On-Site== |
− | + | * New tower w/ enclosure & guy wires | |
− | Garden web cam | + | * Garden web cam |
− | + | * Pluvio 1 (Currently installed but broken) | |
− | Pluvio 1 | + | * Met Station w/ soil thermocouples, radiation, lake sensors on rusted tripod |
− | + | * New Multiplexer | |
− | Met Station w/ soil thermocouples, radiation, lake sensors on rusted tripod | + | * Pluvio 2 (needs to be installed but is in the environmental data center)... has a different base than the existing one. |
+ | * Pluvio 2 base is inside the wyoming gauge snow fence sitting on the ground | ||
== Goals == | == Goals == | ||
− | + | * Mount recalibrated AT/RH sensors | |
− | Mount recalibrated | + | * Move power to the new enclosure |
− | + | * Transfer as much equipment as possible to new tower | |
− | Transfer as much equipment as possible to new tower | + | * Leave what can't be moved at the old site |
− | + | * Install Pluvio 2 | |
− | Leave what can't be moved at the old site | + | ** note, pluvio 1 wire is a bit short. but should be okay with pluvio 2 |
− | + | * Get evaporation pan working | |
− | Install Pluvio 2 | + | * Install new radiometer |
− | + | * Tighten guy wires and level tower | |
− | Get | ||
− | |||
− | Install new radiometer | ||
− | |||
− | Tighten guy wires and level tower | ||
== Needs == | == Needs == | ||
+ | * [[TFS Site Wiring]] / cable lengths | ||
+ | * List cable types needed '''''?''''' | ||
+ | * List muxes needed '''''?''''' | ||
− | + | ==List equipment/tools need to bring== | |
− | + | * Conduit | |
− | + | * New Program (Bob Bu has draft) | |
− | + | * Troubleshoot Evaporation Pan | |
− | + | * Figure out what needs calibration | |
− | |||
− | |||
− | Conduit | ||
− | |||
− | New Program (Bob Bu has draft) | ||
− | |||
− | Troubleshoot Evaporation Pan | ||
− | |||
− | Figure out what needs calibration | ||
== Updates == | == Updates == | ||
− | + | * Pluvio 1 and Pluvio 2 use different base stands. Make sure to include the Pluvio 2 mounting hardware! | |
− | + | * Evaporation pan may not be in the budget this year if the gauging unit (Campbell 21531) needs to be replaced. | |
− | + | * Conduit isn't an immediate priority since this depends on the final setup. | |
− | |||
− |
Revision as of 09:44, 4 May 2013
Contents
Overview
The met station at Toolik needs to be transferred from its tripod to a tower. The field requirements for this assignment will be outlined here.
To Bring from Fairbanks
- Cabling to extend thermocouple temperature profile from old enclosure to new enclosure.
- shovels for digging out buried cabling
- extension cord
- cable splicing tools
- soldering iron
- butane
- propane torch
- solder
- heat shrink
- extra cabling
- Toolbags
- Extra data logger (CR1000, for any instruments that aren't transferred to the new logger on this trip and or don't reach... completely just a back up item)
- small actionpacker
- sled
- Climbing harness
Current Equipment On-Site
- New tower w/ enclosure & guy wires
- Garden web cam
- Pluvio 1 (Currently installed but broken)
- Met Station w/ soil thermocouples, radiation, lake sensors on rusted tripod
- New Multiplexer
- Pluvio 2 (needs to be installed but is in the environmental data center)... has a different base than the existing one.
- Pluvio 2 base is inside the wyoming gauge snow fence sitting on the ground
Goals
- Mount recalibrated AT/RH sensors
- Move power to the new enclosure
- Transfer as much equipment as possible to new tower
- Leave what can't be moved at the old site
- Install Pluvio 2
- note, pluvio 1 wire is a bit short. but should be okay with pluvio 2
- Get evaporation pan working
- Install new radiometer
- Tighten guy wires and level tower
Needs
- TFS Site Wiring / cable lengths
- List cable types needed ?
- List muxes needed ?
List equipment/tools need to bring
- Conduit
- New Program (Bob Bu has draft)
- Troubleshoot Evaporation Pan
- Figure out what needs calibration
Updates
- Pluvio 1 and Pluvio 2 use different base stands. Make sure to include the Pluvio 2 mounting hardware!
- Evaporation pan may not be in the budget this year if the gauging unit (Campbell 21531) needs to be replaced.
- Conduit isn't an immediate priority since this depends on the final setup.