To Do: | To Do: | ||
* Change out snow transducers, 8 pieces | * Change out snow transducers, 8 pieces | ||
Line 6: | Line 5: | ||
* level radiometers | * level radiometers | ||
* Fix C site Rim Snow Sensor | * Fix C site Rim Snow Sensor | ||
− | + | * D Thermal Conductivity | |
+ | ** Program works fine in Fairbanks | ||
+ | ** Data Points From April Trip: | ||
+ | *** Heater Resistance #1 -- 68.2 ohms | ||
+ | *** Heater Resistance #2 -- 70.2 ohms | ||
+ | *** Heater Resistance #3 -- 70.4 ohms | ||
+ | *** Heater Resistance #4 -- 70.7 ohms | ||
+ | *** Heater Resistance #5 -- 69.1 ohms | ||
+ | *** Heater Resistance #6 -- 70.3 ohms | ||
+ | *** Thermal conductivity thermistor resistance #1 -- 57.6 kohms | ||
+ | *** Thermal conductivity thermistor resistance #2 -- 57.8 kohms | ||
+ | *** Thermal conductivity thermistor resistance #3 -- 58.2 kohms | ||
+ | *** Thermal conductivity thermistor resistance #4 -- 57.5 kohms | ||
+ | *** Thermal conductivity thermistor resistance #5 -- 58.0 kohms | ||
+ | *** Thermal conductivity thermistor resistance #6 -- 58.4 kohms | ||
+ | * OKAY... Look at how it is wired in the field. / in pictures. I think there are two pulse port instructions when there should be just one but I don't know for sure until I review the photos / see it in person. | ||
+ | * Basically there are two | ||
To Bring: | To Bring: | ||
* Two CNR4 Net Radiometers | * Two CNR4 Net Radiometers | ||
** One for B and one for D (or.... retap the D radiometer up there... might try that first.) | ** One for B and one for D (or.... retap the D radiometer up there... might try that first.) |
Revision as of 15:57, 15 August 2014
To Do:
- Change out snow transducers, 8 pieces
- swap back the B site net radiometer
- change out desiccant in the D site radiometer
- level radiometers
- Fix C site Rim Snow Sensor
- D Thermal Conductivity
- Program works fine in Fairbanks
- Data Points From April Trip:
- Heater Resistance #1 -- 68.2 ohms
- Heater Resistance #2 -- 70.2 ohms
- Heater Resistance #3 -- 70.4 ohms
- Heater Resistance #4 -- 70.7 ohms
- Heater Resistance #5 -- 69.1 ohms
- Heater Resistance #6 -- 70.3 ohms
- Thermal conductivity thermistor resistance #1 -- 57.6 kohms
- Thermal conductivity thermistor resistance #2 -- 57.8 kohms
- Thermal conductivity thermistor resistance #3 -- 58.2 kohms
- Thermal conductivity thermistor resistance #4 -- 57.5 kohms
- Thermal conductivity thermistor resistance #5 -- 58.0 kohms
- Thermal conductivity thermistor resistance #6 -- 58.4 kohms
- OKAY... Look at how it is wired in the field. / in pictures. I think there are two pulse port instructions when there should be just one but I don't know for sure until I review the photos / see it in person.
- Basically there are two
To Bring:
- Two CNR4 Net Radiometers