Line 2: Line 2:
 
*bring measuring cup set for leveling UVA and UVB sensors
 
*bring measuring cup set for leveling UVA and UVB sensors
 
*wire junction to split all instruments needing 12V from logger
 
*wire junction to split all instruments needing 12V from logger
*swap in fancier wind sensor
 
*fill in serial numbers of all instruments/loggers on google sheet
 
*swap out HMP155s
 
**write down which height is which SN
 
 
*swap out quantum sensors
 
*swap out quantum sensors
 
**bring mini wrench to replace them
 
**bring mini wrench to replace them
 
**<s>figure out what the connection is like at toolik</s>
 
**<s>figure out what the connection is like at toolik</s>
 
**<s>change calibration constant?</s>
 
**<s>change calibration constant?</s>
*swap CNR4
 
 
*remove old radio
 
*remove old radio
 
*get field books from Brie
 
*get field books from Brie
 +
*swap CNR4, change constants in program
 +
 +
 +
 
*install new barometer
 
*install new barometer
 
**change program calibration constants
 
**change program calibration constants
*change UVA + UVB program calibration constants: UVA:0.0221, UVB: 0.00178 (per Lija's email)
+
 
 
*we zero out the CMP6, but not the CNR4. reconsider?
 
*we zero out the CMP6, but not the CNR4. reconsider?
  
 
==install new evap pan==
 
==install new evap pan==
**leak test (marine epoxy in case of leaks. should be up in the EDC office)
+
*leak test (marine epoxy in case of leaks. should be up in the EDC office)
**clean out bottom
+
*clean out bottom
**field calibrate
+
*field calibrate
Calibrate
 
  
 
     Fill pan partway with water, measure height with ruler in mm
 
     Fill pan partway with water, measure height with ruler in mm
Line 45: Line 43:
 
**need usb cable  
 
**need usb cable  
  
==download garden cam images==
+
==Brie Helps with==
 +
*swap in fancier wind sensor 5108-45-12M
 +
*swap out HMP155s
 +
**write down which height is which SN
 +
*download garden cam images
 
** bring replacement batteries
 
** bring replacement batteries
 
** to turn off: press and hold organge power button until 3 beeps and green LED turns off
 
** to turn off: press and hold organge power button until 3 beeps and green LED turns off
Line 62: Line 64:
 
*possible tipping bucket calibration
 
*possible tipping bucket calibration
 
*possible pluvio calibration
 
*possible pluvio calibration
*UVA+UVB corrections
+
*UVA+UVB corrections. UVA:0.0221, UVB: 0.00178 (per Lija's email)
 +
*CNR4 constants
 +
**LW up: 7.51
 +
**LW down: 8.24
 +
**SW up: 16.77
 +
**SW down: 14.82
 +
 
 +
==get SN of all instruments/loggers on google sheet==
 +
*datalogger,mux, radios, nl__
 +
*both wind sensors,cmp4, cmp6, evap gauge, precips
 +
*basically everything
  
 
==To change on instrumentation website==
 
==To change on instrumentation website==
Line 71: Line 83:
  
 
==to bring==
 
==to bring==
**laptop + charger
+
*laptop + charger
**field laptop + charger
+
*field laptop + charger
**tipping bucket calibration box
+
*tipping bucket calibration box
**gloves, hat(warm and sun)
+
*gloves, hat(warm and sun)
**tools
+
*tools
**wire junction
+
*wire junction
**hiking boots,rubber boots,running shoes
+
*hiking boots,rubber boots,running shoes
**field book
+
*field book
**usb cable for pluvio
+
*usb cable for pluvio
**batteries for garden cam
+
*batteries for garden cam
**cookies for brie
+
*cookies for brie
**instruments
+
*instruments
***anemometer
+
**anemometer
***CNR4
+
**CNR4
***Two HMP155s
+
**Two HMP155s
 +
**baromter
 +
**quantum

Revision as of 11:35, 3 June 2016

  • bring measuring cup set for leveling UVA and UVB sensors
  • wire junction to split all instruments needing 12V from logger
  • swap out quantum sensors
    • bring mini wrench to replace them
    • figure out what the connection is like at toolik
    • change calibration constant?
  • remove old radio
  • get field books from Brie
  • swap CNR4, change constants in program


  • install new barometer
    • change program calibration constants
  • we zero out the CMP6, but not the CNR4. reconsider?

install new evap pan

  • leak test (marine epoxy in case of leaks. should be up in the EDC office)
  • clean out bottom
  • field calibrate
   Fill pan partway with water, measure height with ruler in mm
   Measure voltage by reading the EvapLevelTemp variable on the program
   Add more water, measure water depth in pan
   Measure voltage
   Calculate multiplier and offset using y = mx+b
       m(multiplier) = (height1-height2)/(voltage2-voltage1)
       b(offset) = height1-(m*voltage1) 

Change multiplier and offset in program


calibrate precip

Tipping bucket

    • fill bottle to line, use smallest orifice, do this 3 times
    • should be 30mm per bottle, so 90mm total
    • change multiplier in program if necessary

Pluvio accuracy test

    • received software in ftp from ott (on my fancy laptop, need to transfer to toughbook)
    • need usb cable

Brie Helps with

  • swap in fancier wind sensor 5108-45-12M
  • swap out HMP155s
    • write down which height is which SN
  • download garden cam images
    • bring replacement batteries
    • to turn off: press and hold organge power button until 3 beeps and green LED turns off
    • remove drive, download and clear images on computer
    • to turn on:press and hold organge power button until green LED lights up. after a few sec beep twice. green LED every 15 sec indicates normal running. if any other beeping or lights, consult manual

take photos of sensors without pics on instrumentation site

  • HMP155
  • wind sensors
  • snow dept
  • barometer
  • evap pan

program changes

  • evap pan calibration
  • possible tipping bucket calibration
  • possible pluvio calibration
  • UVA+UVB corrections. UVA:0.0221, UVB: 0.00178 (per Lija's email)
  • CNR4 constants
    • LW up: 7.51
    • LW down: 8.24
    • SW up: 16.77
    • SW down: 14.82

get SN of all instruments/loggers on google sheet

  • datalogger,mux, radios, nl__
  • both wind sensors,cmp4, cmp6, evap gauge, precips
  • basically everything

To change on instrumentation website

    • pluvio is actually version 2
    • lake temp measurement
    • barometer


to bring

  • laptop + charger
  • field laptop + charger
  • tipping bucket calibration box
  • gloves, hat(warm and sun)
  • tools
  • wire junction
  • hiking boots,rubber boots,running shoes
  • field book
  • usb cable for pluvio
  • batteries for garden cam
  • cookies for brie
  • instruments
    • anemometer
    • CNR4
    • Two HMP155s
    • baromter
    • quantum