Difference between revisions of "Oliktok precip site"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
+ | ===Barrow site=== | ||
+ | Has: | ||
+ | *Enclosure | ||
+ | *CR1000 | ||
+ | *Judd or SR50a | ||
+ | *Radios/NL100 | ||
+ | |||
+ | Needs: | ||
+ | *LPM | ||
+ | *Quadpod for: | ||
+ | *3x SR50a | ||
+ | |||
+ | ===Atqasuk=== | ||
+ | Uninstalling: | ||
+ | *Nipher guage | ||
+ | *CR1000 | ||
+ | *2 radios | ||
+ | *Wenglor particle counter | ||
+ | *SR50a | ||
+ | *quadpod | ||
+ | *computer? | ||
+ | |||
+ | ===Oliktok=== | ||
+ | Installing: | ||
+ | *Geonor + fence | ||
+ | *Power AC | ||
+ | *SR50a on quadpod | ||
+ | *LPM | ||
+ | |||
+ | |||
Geonor notes | Geonor notes | ||
*needs antifreeze sol'n: Propylene glycol (40%) / Methanol (60%) | *needs antifreeze sol'n: Propylene glycol (40%) / Methanol (60%) |
Revision as of 15:07, 8 August 2016
Barrow site
Has:
- Enclosure
- CR1000
- Judd or SR50a
- Radios/NL100
Needs:
- LPM
- Quadpod for:
- 3x SR50a
Atqasuk
Uninstalling:
- Nipher guage
- CR1000
- 2 radios
- Wenglor particle counter
- SR50a
- quadpod
- computer?
Oliktok
Installing:
- Geonor + fence
- Power AC
- SR50a on quadpod
- LPM
Geonor notes
- needs antifreeze sol'n: Propylene glycol (40%) / Methanol (60%)
- needs 0.4L Low Pour Hydraulic oil
- Geonor fence
- Alter shield
- attach shield to Geonor stand with 1in pipe, then 1in to 3/4in nurail offset cross fitting like (http://www.nurail.com/products/%2310-Offset-Cross-%252d-3%7B47%7D4in-x-1in..html), then 3/4in post provided with the alter shield
- Alter shield
Power
- LPM uses max 150 VA (VA = watts)
- Geonor heater draws 25 watts at 24 volts
- 3.4 mA per vibrating wire. 7 mA on warm up
- SR50a
- 250 mA peak measurement (measurement takes less than 1 sec)
- 1 mA quiescent in SDI12 mode
Todo
- asked alaska steel for nurail quote, do PR when receive it
- sent PR to wanda for home depot
Site Location