***attach shield to Geonor stand with 1in pipe, then 1in to 3/4in nurail offset cross fitting like (http://www.nurail.com/products/%2310-Offset-Cross-%252d-3%7B47%7D4in-x-1in..html), then 3/4in post provided with the alter shield | ***attach shield to Geonor stand with 1in pipe, then 1in to 3/4in nurail offset cross fitting like (http://www.nurail.com/products/%2310-Offset-Cross-%252d-3%7B47%7D4in-x-1in..html), then 3/4in post provided with the alter shield | ||
− | + | ***apply rust prevention coating | |
Power | Power | ||
*LPM uses max 150 VA (VA = watts) | *LPM uses max 150 VA (VA = watts) |
Revision as of 16:17, 8 August 2016
Barrow site
Has:
- Enclosure
- CR1000
- Judd or SR50a
- Radios/NL100
Needs:
- LPM
- Quadpod for:
- 3x SR50a
Atqasuk
Uninstalling:
- Nipher guage
- CR1000
- 2 radios
- Wenglor particle counter
- SR50a
- quadpod
- computer?
Oliktok
Installing:
- Geonor + fence
- Power AC
- SR50a on quadpod
- LPM
Geonor notes
- needs antifreeze sol'n: Propylene glycol (40%) / Methanol (60%)
- needs 0.4L Low Pour Hydraulic oil
- Geonor fence
- Alter shield
- attach shield to Geonor stand with 1in pipe, then 1in to 3/4in nurail offset cross fitting like (http://www.nurail.com/products/%2310-Offset-Cross-%252d-3%7B47%7D4in-x-1in..html), then 3/4in post provided with the alter shield
- apply rust prevention coating
- Alter shield
Power
- LPM uses max 150 VA (VA = watts)
- Geonor heater draws 25 watts at 24 volts
- 3.4 mA per vibrating wire. 7 mA on warm up
- SR50a
- 250 mA peak measurement (measurement takes less than 1 sec)
- 1 mA quiescent in SDI12 mode
Todo
- asked alaska steel for nurail quote, do PR when receive it
- figure out geonor fence
- figure out geonor heater
- programs
- update Barrow (downloaded one from bob's dropbox, now in docs folder)
- write new for oliktok
- LPM communication
- quadpods
Site Location