* '''TAKE SR50 cable''' to site, estimated 40-feet ('''but check design specs!''') | * '''TAKE SR50 cable''' to site, estimated 40-feet ('''but check design specs!''') | ||
− | + | * return/replace site logbook to enclosure | |
=site logs= | =site logs= | ||
Line 26: | Line 26: | ||
* conduits '''wired''' (using tie-wire) to enclosure entry fittings to secure | * conduits '''wired''' (using tie-wire) to enclosure entry fittings to secure | ||
− | |||
* soil temp profile cable: added strain relief using hose clamp & cord; load was on the multiplexer terminals | * soil temp profile cable: added strain relief using hose clamp & cord; load was on the multiplexer terminals | ||
− | |||
* added cord inside enclosure to secure extra/loose cables inside | * added cord inside enclosure to secure extra/loose cables inside | ||
− | |||
* replaced rain gauge | * replaced rain gauge | ||
** model: TR-525USW | ** model: TR-525USW | ||
Line 36: | Line 33: | ||
** collector/funnel secured with hose clamp | ** collector/funnel secured with hose clamp | ||
** screen secured with electrical tape | ** screen secured with electrical tape | ||
− | |||
− | |||
− | |||
Line 44: | Line 38: | ||
* installed electric fence with 3 posts | * installed electric fence with 3 posts | ||
− | |||
* no time to fix site cables | * no time to fix site cables | ||
− | |||
* '''LOTS''' of fox scat around site, many chewed cables | * '''LOTS''' of fox scat around site, many chewed cables | ||
+ | * accidentally removed site logbook |
Revision as of 21:11, 10 July 2007
Contents
Bullen Point met
site TODO list
- record as-built wiring of soil sensors
- Flex conduit as needed
- TAKE SR50 cable to site, estimated 40-feet (but check design specs!)
- return/replace site logbook to enclosure
site logs
14 June 2007, Ken I., Doug K.
- net radiometer replaced
- s/n 052046
- 14.6 uV/W-m^2
- 120 cm centerline sensor to ground
- SR50 -- cable missing, not replaced (had one, but too short)
- RMYoung & HMP45C cables put in flex conduit on tripod
- no GWS-YSI sensor, and no conduit was left for it
- AT shields braced with mast/enclosure bracket to strengthen
- antenna cable wrapped with nylon spiral wrap; no way to pull into conduit
- conduits wired (using tie-wire) to enclosure entry fittings to secure
- soil temp profile cable: added strain relief using hose clamp & cord; load was on the multiplexer terminals
- added cord inside enclosure to secure extra/loose cables inside
- replaced rain gauge
- model: TR-525USW
- s/n: 37655-1205
- collector/funnel secured with hose clamp
- screen secured with electrical tape
13 June 2007, Ken I., Doug K.
- installed electric fence with 3 posts
- no time to fix site cables
- LOTS of fox scat around site, many chewed cables
- accidentally removed site logbook