== 15 June 2007, Ken I., Doug K. == | == 15 June 2007, Ken I., Doug K. == | ||
* fixed 10m RMYoung wiring, details follow: | * fixed 10m RMYoung wiring, details follow: | ||
− | + | ** reconnected RMYoung wiring at sensor wiring box to nominal: | |
− | * reconnected RMYoung wiring at sensor wiring box to nominal: | + | *** WS SIG -- RED -- 6 |
− | ** WS SIG -- RED -- 6 | + | *** WS REF -- BLK -- 2 |
− | ** WS REF -- BLK -- 2 | + | *** WD EX -- BLU -- 5 |
− | ** WD EX -- BLU -- 5 | + | *** WD SIG -- GRN -- 4 |
− | ** WD SIG -- GRN -- 4 | + | *** WD REF -- WHT -- 3 |
− | ** WD REF -- WHT -- 3 | + | *** DRAIN -- CLR -- 1 |
− | ** DRAIN -- CLR -- 1 | ||
− | * used spare piece of 05103-CSI cable at logger-shack end: | + | ** used spare piece of 05103-CSI cable at logger-shack end: |
− | ** per program listing with timestamp 07jun07 02:35:43 | + | *** per program listing with timestamp 07jun07 02:35:43 |
− | ** WS is on C7 | + | *** WS is on C7 |
− | ** WD on SE3 (which is multiplexer) | + | *** WD on SE3 (which is multiplexer) |
− | * wiring from logger to multiplexer: | + | ** wiring from logger to multiplexer: |
− | ** SE3 -- CLR -- COM H1 | + | *** SE3 -- CLR -- COM H1 |
− | ** SE4 -- BLK -- COM L1 | + | *** SE4 -- BLK -- COM L1 |
− | ** AG -- BLK -- COM L2 | + | *** AG -- BLK -- COM L2 |
− | ** E2 -- RED -- COM H2 | + | *** E2 -- RED -- COM H2 |
− | * connected 10m WS to P1 & G via wiring board terminal blocks, at lower left, left to right, from multiplexer to sensor on tower: | + | ** connected 10m WS to P1 & G via wiring board terminal blocks, at lower left, left to right, from multiplexer to sensor on tower: |
− | ** empty | + | *** empty |
− | ** empty | + | *** empty |
− | ** mplx 7L2 -- BLK -- WHT to sensor | + | *** mplx 7L2 -- BLK -- WHT to sensor |
− | ** mplx 7H1 -- BLK -- GRN | + | *** mplx 7H1 -- BLK -- GRN |
− | ** mplx 7H2 -- RED -- BLU | + | *** mplx 7H2 -- RED -- BLU |
− | ** CR10X P1 -- RED | + | *** CR10X P1 -- RED |
− | ** CR10X G -- BLK | + | *** CR10X G -- BLK |
− | * spliced sensor-to-4C cable at either end: | + | ** spliced sensor-to-4C cable at either end: |
− | ** WHT -- WHT cable 1 | + | *** WHT -- WHT cable 1 |
− | ** GRN -- GRN cable 1 | + | *** GRN -- GRN cable 1 |
− | ** BLU -- RED cable 1 | + | *** BLU -- RED cable 1 |
− | ** RED -- RED cable 2 | + | *** RED -- RED cable 2 |
− | ** BLK -- BLK cable 2 | + | *** BLK -- BLK cable 2 |
Revision as of 11:41, 3 July 2007
site TODO list
- record as-built wiring of soil sensors
- Flex conduit as needed
site logs
15 June 2007, Ken I., Doug K.
- fixed 10m RMYoung wiring, details follow:
- reconnected RMYoung wiring at sensor wiring box to nominal:
- WS SIG -- RED -- 6
- WS REF -- BLK -- 2
- WD EX -- BLU -- 5
- WD SIG -- GRN -- 4
- WD REF -- WHT -- 3
- DRAIN -- CLR -- 1
- reconnected RMYoung wiring at sensor wiring box to nominal:
- used spare piece of 05103-CSI cable at logger-shack end:
- per program listing with timestamp 07jun07 02:35:43
- WS is on C7
- WD on SE3 (which is multiplexer)
- used spare piece of 05103-CSI cable at logger-shack end:
- wiring from logger to multiplexer:
- SE3 -- CLR -- COM H1
- SE4 -- BLK -- COM L1
- AG -- BLK -- COM L2
- E2 -- RED -- COM H2
- wiring from logger to multiplexer:
- connected 10m WS to P1 & G via wiring board terminal blocks, at lower left, left to right, from multiplexer to sensor on tower:
- empty
- empty
- mplx 7L2 -- BLK -- WHT to sensor
- mplx 7H1 -- BLK -- GRN
- mplx 7H2 -- RED -- BLU
- CR10X P1 -- RED
- CR10X G -- BLK
- connected 10m WS to P1 & G via wiring board terminal blocks, at lower left, left to right, from multiplexer to sensor on tower:
- spliced sensor-to-4C cable at either end:
- WHT -- WHT cable 1
- GRN -- GRN cable 1
- BLU -- RED cable 1
- RED -- RED cable 2
- BLK -- BLK cable 2
- spliced sensor-to-4C cable at either end: