Difference between revisions of "2018 NGEE Fall Utqiagvik Trip"

From IARC 207 Wiki
Jump to navigation Jump to search
(Created page with "* Site C HMP155 * Check level of radiometers * Replace SR50A transducers * Check level of tipping buckets *")
 
Line 1: Line 1:
* Site C HMP155
+
===To Do===
 +
 
 +
 
 +
* Intensive Site A HMP155 failed (3.5m)
 +
* Intensive Site B HMP155 failed (1.4m)
 +
* Intensive Site C HMP155 failed
 +
* Have 2-3 additional HMP155 membrane tips
 +
* need to replace the network cable running from the computer to the network switch.  It cuts out with minimal bumping...
 +
* Site A SR50A transducers have failed
 +
* Check level of tipping buckets
 
* Check level of radiometers
 
* Check level of radiometers
* Replace SR50A transducers
+
** replace radiometer desiccant
* Check level of tipping buckets
+
** polish radiometer domes
*
+
* some subsurface items are beginning to fail.
 +
* label the computer
 +
* bring up the nuc plate and wood screws and other screw packet to mount nuc to wall
 +
* troubleshoot the network connection in control shed.
 +
* take new pictures of inside control shed
 +
 
 +
===To Bring===
 +
* Tools
 +
** CSI Phillips for opening CNR4 radiometers and SR50A
 +
** Tap & Die in case any more radiometer screws strip
 +
** torpedo level for tipping bucket level
 +
** 5/16" screw driver for tipping bucket level
 +
** electrical tape for HMP155 replacement
 +
** Antenna & coax for C site to get antenna outside of the box. (two different antennas will decide on which up in Utqiagvik)
 +
** Drill & battery for potential tap & die stuff
 +
 
 +
 
 +
===On Site===
 +
* Should be a ladder at the NGEE Flux tower for use replacing 3.5m instruments

Revision as of 12:19, 29 September 2018

To Do

  • Intensive Site A HMP155 failed (3.5m)
  • Intensive Site B HMP155 failed (1.4m)
  • Intensive Site C HMP155 failed
  • Have 2-3 additional HMP155 membrane tips
  • need to replace the network cable running from the computer to the network switch. It cuts out with minimal bumping...
  • Site A SR50A transducers have failed
  • Check level of tipping buckets
  • Check level of radiometers
    • replace radiometer desiccant
    • polish radiometer domes
  • some subsurface items are beginning to fail.
  • label the computer
  • bring up the nuc plate and wood screws and other screw packet to mount nuc to wall
  • troubleshoot the network connection in control shed.
  • take new pictures of inside control shed

To Bring

  • Tools
    • CSI Phillips for opening CNR4 radiometers and SR50A
    • Tap & Die in case any more radiometer screws strip
    • torpedo level for tipping bucket level
    • 5/16" screw driver for tipping bucket level
    • electrical tape for HMP155 replacement
    • Antenna & coax for C site to get antenna outside of the box. (two different antennas will decide on which up in Utqiagvik)
    • Drill & battery for potential tap & die stuff


On Site

  • Should be a ladder at the NGEE Flux tower for use replacing 3.5m instruments