===Utq To Do=== | ===Utq To Do=== | ||
+ | ====General==== | ||
+ | * Bring electrical tape to re-cover HMP155 sensor ends for moisture protection | ||
+ | * Bring grease / anti corrosion compound for electrical connections | ||
+ | * Bring SR50A transducers | ||
+ | * Bring Net Radiometer Desiccant | ||
+ | ====Site A==== | ||
+ | * Replace 2x SR50A transducers | ||
+ | * Replace HMP155 failed (3.5m) | ||
+ | * Replace tip on HMP155 (1.4m) | ||
+ | * Level Tipping Bucket | ||
+ | * Level Radiometer | ||
+ | * Change Radiometer Desiccant | ||
+ | * Polish Radiometer domes | ||
− | * | + | ====Site B==== |
+ | * Replace 2x SR50A transducers | ||
* Intensive Site B HMP155 failed (1.4m) | * Intensive Site B HMP155 failed (1.4m) | ||
+ | * Level Tipping Bucket | ||
+ | * Level Radiometer | ||
+ | * Change Radiometer Desiccant | ||
+ | * Polish Radiometer domes | ||
+ | |||
+ | ====Site C==== | ||
+ | * Replace 3x SR50A transducers | ||
* Intensive Site C HMP155 failed | * Intensive Site C HMP155 failed | ||
− | * | + | * Level Tipping Bucket |
− | ** | + | * Level Radiometer |
+ | * Change Radiometer Desiccant | ||
+ | * Polish Radiometer domes | ||
+ | * Check connection to soil moisture grid logger MD485 relay | ||
+ | * Move antenna outside of box and if needed, use fish tape for this step | ||
+ | ** have also included some extra duct seal if needed for re-sealing of box | ||
+ | |||
+ | ====Site D==== | ||
+ | * Replace 1x SR50A transducers | ||
+ | * Replace tip on HMP155 (1.4m) | ||
+ | * Level Radiometer | ||
+ | * Change Radiometer Desiccant | ||
+ | * Polish Radiometer domes | ||
+ | |||
+ | ====BEO Control Shed==== | ||
* need to replace the network cable running from the computer to the network switch. It cuts out with minimal bumping... | * need to replace the network cable running from the computer to the network switch. It cuts out with minimal bumping... | ||
** I think I almost need to connect the computer to a screen to see where the hang up is if it indeed turned on so I'll bring my light keyboard/mouse and an HDMI to DVI cord. | ** I think I almost need to connect the computer to a screen to see where the hang up is if it indeed turned on so I'll bring my light keyboard/mouse and an HDMI to DVI cord. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
* label the computer | * label the computer | ||
* bring up the nuc plate and wood screws and other screw packet to mount nuc to wall | * bring up the nuc plate and wood screws and other screw packet to mount nuc to wall |
Revision as of 14:03, 29 September 2018
Contents
Fairbanks todo
- pull out necessary tools
- pack gear
- pack daypack
- charge drill
- assemble food & drink
Important Times
- Flight: Alaska 192 Departs: Fairbanks (FAI) on Mon, Oct 1 at 11:00 am
- Sunrise: Oct 2 at 8:50 AM
- Flight: Alaska 50 Departs: Barrow (BRW) on Tue, Oct 2 at 7:09 pm
Utq To Do
General
- Bring electrical tape to re-cover HMP155 sensor ends for moisture protection
- Bring grease / anti corrosion compound for electrical connections
- Bring SR50A transducers
- Bring Net Radiometer Desiccant
Site A
- Replace 2x SR50A transducers
- Replace HMP155 failed (3.5m)
- Replace tip on HMP155 (1.4m)
- Level Tipping Bucket
- Level Radiometer
- Change Radiometer Desiccant
- Polish Radiometer domes
Site B
- Replace 2x SR50A transducers
- Intensive Site B HMP155 failed (1.4m)
- Level Tipping Bucket
- Level Radiometer
- Change Radiometer Desiccant
- Polish Radiometer domes
Site C
- Replace 3x SR50A transducers
- Intensive Site C HMP155 failed
- Level Tipping Bucket
- Level Radiometer
- Change Radiometer Desiccant
- Polish Radiometer domes
- Check connection to soil moisture grid logger MD485 relay
- Move antenna outside of box and if needed, use fish tape for this step
- have also included some extra duct seal if needed for re-sealing of box
Site D
- Replace 1x SR50A transducers
- Replace tip on HMP155 (1.4m)
- Level Radiometer
- Change Radiometer Desiccant
- Polish Radiometer domes
BEO Control Shed
- need to replace the network cable running from the computer to the network switch. It cuts out with minimal bumping...
- I think I almost need to connect the computer to a screen to see where the hang up is if it indeed turned on so I'll bring my light keyboard/mouse and an HDMI to DVI cord.
- label the computer
- bring up the nuc plate and wood screws and other screw packet to mount nuc to wall
- troubleshoot the network connection in control shed.
- take new pictures of inside control shed
To Bring
- Tools
- CSI Phillips for opening CNR4 radiometers and SR50A
- Tap & Die in case any more radiometer screws strip
- torpedo level for tipping bucket level
- 5/16" screw driver for tipping bucket level
- electrical tape for HMP155 replacement
- Antenna & coax for C site to get antenna outside of the box. (two different antennas will decide on which up in Utqiagvik)
- Drill & battery for potential tap & die stuff
On Site
- Should be a ladder at the NGEE Flux tower for use replacing 3.5m instruments