===Instrumentation and Heights===
 +
* AT/RH @ 1.85m
 +
** Vaisala HMP155
 +
** https://www.campbellsci.com/hmp155a
 +
** Temperature Range: -80 to +60 Celsius
 +
** Temperature Accuracy: (0.226 - 0.0028 x temperature)°C (-80° to +20°C)
 +
** Humidity Range: 0 to 100 % Relative Humidity
 +
** Humidity Accuracy: ±(1.2 + 0.012 × reading) % RH (at -40° to -20°C); ±(1.0 + 0.008 × reading) % RH (at -20° to +40°C)
 +
* WS/WD @ 3.74m
 +
** RM Young 01503
 +
** https://www.campbellsci.com/05103-l
 +
** Range: 0 to 100 m/s
 +
** Accuracy: +-0.3m/s
 +
** Startup threshold: 1.0 m/s
 +
** Wind Direction measurement band: 0 to 355 degrees
 +
** Accuracy: +-3 degrees
 +
* Snow Depth @ Tripod
 +
** Campbell Scientific SR50A
 +
** https://www.campbellsci.com/sr50a
 +
** Resolution: 0.25mm
 +
** Accuracy: +-1.0 cm
 +
* Snow Depth @ Lump
 +
** Campbell Scientific SR50A
 +
** https://www.campbellsci.com/sr50a
 +
** Resolution: 0.25mm
 +
** Accuracy: +-1.0 cm 
 +
* Net Radiation @ 1.5m
 +
** Kipp & Zonen CNR4
 +
** https://www.campbellsci.com/cnr4
 +
** Shortwave Measurement Range-  305 to 2800 nm
 +
** Shortwave Uncertainty in total daily -  < 5% (The uncertainty values are for a 95% confidence level.) 
 +
** Longwave Measurement Range -  4500 to 42,000 nm
 +
** Longwave Uncertainty in total daily-  < 10% (The uncertainty values are for a 95% confidence level.)
 +
* Skin Temperature @ 1.9m:
 +
** Apogee Instruments SI-111
 +
** https://www.campbellsci.com/si-111
 +
** Operating Range: -55 to +80 C
 +
** Accuracy: ±0.2°C (-10° to +65°C) & ±0.5°C (-40° to +70°C)
 +
** Field of View:  22° half angle
 +
* Summer Precipitation
 +
** Texas Instruments TE525MM Metric model
 +
** https://www.campbellsci.com/te525mm-l
 +
** Accuracy:  1.0% up to 50 mm/hr
 +
* Soil Moisture
 +
** Stevens Hydrasense II
 +
** https://amarillo.nserl.purdue.edu/ceap/metadata/Stevens_Hydra_soil.pdf
 +
** Range Dielectric Constant: 1 = Air to 78 = Distilled Water
 +
** Accuracy Dielectric Constant: ±1.5% or 0.2 whichever is greater
 +
** Soil Moisture Range: Completely Dry to completely saturated
 +
** Soil Moisture Accuracy: ±0.03 water fraction by volume in typical soil
 +
** Conductivity Range: 0.01 to 1.5 Siemens per meter
 +
** Conductivity Accuracy: ±2.0% or 0.005 S/m whichever is greater
 +
** Temperature Range: -10 to +65 Degrees Celsius
 +
** Temperature Accuracy: ±0.1 Degrees Celsius
 +
* Soil Heat Flux
 +
** https://www.campbellsci.com/hfp01
 +
** Sensitivity:  50 μV W-1 m-2 (nominal)
 +
** Accuracy:  Within -15% to +5% in most common soils (12 hour totals)
 +
* Snow Temperature
 +
** Thermistor - US Sensor PS302J2
 +
** https://www.littelfuse.com/~/media/electronics/datasheets/leaded_thermistors/littelfuse_leaded_thermistors_interchangeable_thermistors_standard_precision_ps_datasheet.pdf.pdf
 +
** Range: -80 to +75 Degrees Celsius
 +
** Accuracy: ±0.1 Degrees Celsius
 +
* Backup Air Temperature
 +
** Thermistor - US Sensor PS302J2
 +
** https://www.littelfuse.com/~/media/electronics/datasheets/leaded_thermistors/littelfuse_leaded_thermistors_interchangeable_thermistors_standard_precision_ps_datasheet.pdf.pdf
 +
** Range: -80 to +75 Degrees Celsius
 +
** Accuracy: ±0.1 Degrees Celsius
 +
* Soil Temperature
 +
** Thermistor -  US Sensor PS103J2
 +
** https://www.littelfuse.com/~/media/electronics/datasheets/leaded_thermistors/littelfuse_leaded_thermistors_interchangeable_thermistors_standard_precision_ps_datasheet.pdf.pdf
 +
** Range: -80 to +75 Degrees Celsius
 +
** Accuracy: ±0.1 Degrees Celsius
 +
* Soil thermal conductivity
 +
** East30 Sensors Thermal Conductivity
 +
** Thermal Conductivity Accuracy: ±5% (Except at soil temperature range about -1.5 to 0.0 Degrees Celsius)
 +
** https://www.east30sensors.com/thermalconductivity
 +
** Temperature Accuracy: ±0.1 Degrees Celsius
 +
* NDVI
 +
** http://publications.metergroup.com/Integrator%20Guide/18310%20SRS-N%20Integrator%20Guide.pdf
 +
** Lower Measurement Band:  650 nm ±2 nm peak wavelengths
 +
** Upper Measurement Band: 810 nm ±2 nm peak wavelengths
 +
** 36 degree field of view
 +
* PRI
 +
** http://publications.metergroup.com/Integrator%20Guide/18311%20SRS-P%20Integrator%20Guide.pdf
 +
** Lower Measurement Band:  532 nm ±2 nm peak wavelengths
 +
** Upper Measurement Band: 570 nm ±2 nm peak wavelengths
 +
** 36 degree field of view

Revision as of 11:06, 3 May 2021

NGEE

Latest

  • Met Data QA'd through: 9/24/2018
  • Radiation Data QA'd through: 9/24/2018
  • Soil through:
  • Snow profile through:
  • Snow through: 2016-2017 season
  • Spectral through:

Met

Met 2016

  • All fixed prior to start of this page... I'll go back and add notes as time allows.
  • But, station put up in early April 2016 as a temporary setup on a
  • Summer Precip Ends: 11/04/2016 02:00
  • Need to revisit data grouper to address the pandas change with respect to NAN and averaging. 10/12/2018 (for AT/RH/DP in 2016 April)

Met 2017

  • all good / corrected... same as above, I will add notes later.
  • Last Winter Season Precip: 04/21/2017 18:00
  • Start of Winter Season for Precip: 10/15/2017 13:00

Met 2018

  • Barometric Pressure good through 6/2018 visit
  • Wind Speed & Direction good through 6/2018 visit
  • Air Temperature / Dewpoint / Relative Humidity good through 6/2018 visit
  • Rain Gage destroyed by moose 12/25/2017.
    • Bucket fixed 6/13/2018 around 21:00 - 22:00 (tips in data were test tips with new bucket).
    • QA file reflects this.

Radiation

Radiation 2016

  • all good / corrected

Radiation 2017

  • all good / corrected

Radiation 2018

  • SW & LW & Skin Temp look good through 6/2018 visit.

Soil

  • I need to dig into the fieldbook notes to see if the VATP jacked at all in 2017.

Soil 2016

Soil 2017

  • Heat Flux plates nonworking until 10/2017

Soil 2018

  • 2018 heat flux plates look decent.
    • it could be that top & bottom are flipped and also that what should be the top is actually flipped in sign?...need to compare to top.
  • VATP
    • Blip during station visit at 6/13/2018 21:00

Snow

Snow 2016-2017

Snow 2017-2018

Station History / Site Downloads / visits:

September 24 & 26 2018

  • B Busey / Bolton / CAS
  • memory problem on logger 9/24 but due to food poisoning just downloaded data.
  • returned 9/26 and upgraded the OS to latest
  • resent program & readdressed.
  • I don't yet know the problem here? Error in CF card perhaps? In 2019 I will replace the CF card with another.

June 13 & 15 2018

  • Station Maintenance @
    • 6/13/2018 20:00 UTC
    • 6/15/2018 20:00 UTC
  • B Busey & N Wales
  • fixed animal damage
    • snow sensor knocked over 12/25/2017
    • tipping bucket removed probably around then, too.
  • fixed program bug

April 10 2016

  • Temporary station built above flood plain. Station put in at end of first snow survey trip of Teller.
  • At that point this was labeled the blue site (the blue electrical tape IDed this site in the logistics phase).
  • Site established around 4/10/2016
    • AT/RH
    • 4 component Radiation
    • Surface water

April 21 - May 5 1 2016

  • Station visited nearly daily during ablation trip

July 2016

  • LC visited and downloaded data.
  • Temporary station had fallen over (knocked by an animal).

August 12 - 22 2016

  • LC & B Busey improve upon site making Teller Bottom site and splitting off the Teller Surface Water Station.
  • Wind Speed / Direction added
  • W

Instrumentation and Heights