Radio -- Freewave FGR S/N 878-5624 CR10X --
1m Vaisala HMP45C Air Temperature / Relative Humidity
8/16/2011 Removed W0510002 8/16/2011 Added T5110026
3m Vaisala HMP45C Air Temperature / Relative Humidity
8/16/2011 Removed U4050048 8/16/2011 Added X3410040
10m Vaisala HMP45C Air Temperature / Relative Humidity
8/5/2009 Added JC2 8/16/2011 Removed JC2 8/16/2011 Added G0110088
1m MetOne 014A Anemometer
8/16/2011 Added M3690
10m RM Young 05103 Anemometer
Campbell Scientific Sonic Distance Sensor, SR50A
8/16/2011 Removed S/N 1201 8/16/2011 Added S/N 3527
Rebs Q7.1 Net Radiometer
Domes Replaced 8/16/2011
Eppley PSP Shortwave Radiometer
Up: PSP-32563F3 Cal: 8.11e-6 V/W/m^2 Down: PSP-32564F3 Cal: 7.84e-6 V/W/m^2
Over 2009/10 winter the cabling to the up facing PSP became damaged in the MIL connector (specifically, a soldered pin to cable connection broke). Intermittent functionality ended around 5/31/2010 and remained broken until the 8/10/2010 site visit. It was broken again by a musk ox on 9/20/2010.
Eppley PIR Longwave Radiometer
Up: PIR-3254F3 Cal: 3.72e-6 V/W/m^2 Down: PIR-32543F3 Cal: 3.34e-6 V/W/m^2
Rain gage
Replaced 8/5/2009
MRC