General Wiring 2013 (Some minor differences like 3 SR50As at site C)
' SE1 -- CNR4 SW In HI ' SE2 -- CNR4 SW In LO ' SE3 -- CNR4 SW OUT HI ' SE4 -- CNR4 SW OUT LO ' SE5 -- CNR4 LW IN HI ' SE6 -- CNR4 LW IN LO ' SE7 -- CNR4 Dome Temperature Signal ' SE8 -- 107 Probe Signal (Red Wire) ' SE9 -- CNR4 LW OUT HI ' SE10 -- CNR4 LW OUT LO ' SE11 -- AM16/32B #3 COM ODD HI ' SE12 -- AM16/32B #3 COM ODD LO ' SE13 -- AM16/32B #1 COM ODD HI, Precision Resistor to VX2 ' SE14 -- AM16/32B #1 COM ODD LO, Precision Resistor to VX2 ' SE15 -- AM16/32B #2 COM ODD HI, Precision Resistor to VX3 ' SE16 -- AM16/32B #2 COM ODD LO, Precision Resistor to VX3
' VX1 -- 107 Probe Excitation (Black Wire); **CNR4 LW Dome Temperature Excitation**, **RM Young WD Excite** ' VX2 -- Precision resistors to Mux 2 COM ODD HI, SE1, COM ODD LO, SE2 ' VX3 -- Precision resistors to Mux 3 COM ODD HI, SE1, COM ODD LO, SE2,
' P1 -- MetOne 1m WS+ ' P2 -- MetOne 3.5m WS+
' C1 -- SDM IO C1 ' C2 -- SDM IO C2 ' C3 -- SDM IO C3 ' C4 -- AM16/32B #1, 2, & 3 -- CLK ' C5 -- SDI 12 Devices Part 1 (6 Vitel Probes ) (Blue Wire) ' C6 -- Vitel Probe CONTROL (Run to SW12V Control for Vitel Probes) ' C7 -- SDI 12 Devices Part 2 (2 SR50A ) (Green Wire) ' C8 -- TE525M Signal ' SW12V -- Radio Power
' Wiring that will need to be moved / extended to the SDM Interface: ' C2 -- AM16/32B #1 -- RES ' C3 -- AM16/32B #2 -- RES ' C8 -- Thermal Conductivity Control
' Signal Ground -- HFP01 Shields (Clear Wire), 107 Probe SG (Purple Wire), SR50A
' SDM Interface Wiring: ' 1 -- AM16/32B #1 RES ' 2 -- AM16/32B #2 RES ' 3 -- AM16/32B #3 RES ' 4 -- Thermal Conductivity Control ' 5 -- HMP155 Control ' 6 -- CNR4 Heater/Fan Control