Oliktok summer 2017 trip

From IARC 207 Wiki
Revision as of 12:48, 7 September 2017 by 137.229.92.185 (talk)
Jump to navigation Jump to search

for telayna

  • replace sr50a transducers
    • 1)unscrew sensor from mount
    • 2)unscrew cable from sensor
    • 3)unscrew all little screws holding the transducer to the sensor body (use the frisbee to work so you don't lose the little screws)
    • 4)unclip the wires of the old transducer, remove the O ring
    • 5)place desiccant in the new transducer
    • 5)place the new O ring on the sensor body and clip the new transducer wire
    • 6)line up the notch of the new transducer on the sensor body
    • 7)screw in all the little screws
    • 8)replace the sensor on the mount and screw in the cable (which is notched)
  • put up temperature sensor
    • mount it as close to SR50a quadpod as possible
    • wiring to CR1000 logger
    • Red -- SW-12
    • yellow -- SE11
    • blue -- SE12
    • clear -- AG
    • black -- AG
    • white -- AG


  • CFM100
    • 1)unplug power from logger
    • 2)plug and screw in the CFM100
    • 3)re-plug power to the logger
    • 4)
  • level geonor
    • there are screws at the base
    • don't do this if it doesn't seem obvious
  • tools i'm sending you with
    • 7/16 nut driver
    • small flathead screw driver
    • small Philips screw driver
    • level

=other

  • antifreeze
  • snip vegetation underneath
    • cable housing
  • plastic cable covers for all cables entering into the logger?