Oliktok summer 2017 trip
for telayna
- replace sr50a transducers
- 1)unscrew sensor from mount
- 2)unscrew cable from sensor
- 3)unscrew all little screws holding the transducer to the sensor body (use the frisbee to work so you don't lose the little screws)
- 4)unclip the wires of the old transducer, remove the O ring
- 5)place desiccant in the new transducer
- 5)place the new O ring on the sensor body and clip the new transducer wire
- 6)line up the notch of the new transducer on the sensor body
- 7)screw in all the little screws
- 8)replace the sensor on the mount and screw in the cable (which is notched)
- put up temperature sensor
- 1)mount it on the south side of the fence
- 2)plug sensor into sensor head
- 3)screw
- 4)zip tie cable to make things neat
- 5)unplug logger before wiring
- wiring to CR1000 logger
- Red -- SW-12
- yellow -- SE11
- blue -- SE12
- clear -- AG
- black -- AG
- white -- AG
- replace putty
- replace power to logger
- CFM100
- 1)unplug power from logger
- 2)plug and screw in the CFM100
- 3)re-plug power to the logger
- 4)insert card
- level geonor
- there are screws at the base
- need to remove cover to access them- and maybe bucket as well
- don't do this if it doesn't seem obvious
- visually inspect panes of LPM
- IF dirty: wipe them with a paper towel or the alcohol swabbies I sent with you
- tools i'm sending you with
- 7/16 nut driver
- small flathead screw driver
- small Philips screw driver
- adjustable wrench
- channel locks
other
- antifreeze
snip vegetation underneath- cable housing
plastic cable covers for all cables entering into the logger?