Ibmet

From IARC 207 Wiki
Revision as of 11:42, 3 July 2007 by imported>Ken
Jump to navigation Jump to search

Imnavait B-site met

site TODO list

  • record as-built wiring of soil sensors
  • Flex conduit as needed

site logs

15 June 2007, Ken I., Doug K.

  • fixed 10m RMYoung wiring, details follow:
    • reconnected RMYoung wiring at sensor wiring box to nominal:
      • WS SIG -- RED -- 6
      • WS REF -- BLK -- 2
      • WD EX -- BLU -- 5
      • WD SIG -- GRN -- 4
      • WD REF -- WHT -- 3
      • DRAIN -- CLR -- 1
    • used spare piece of 05103-CSI cable at logger-shack end:
      • per program listing with timestamp 07jun07 02:35:43
      • WS is on C7
      • WD on SE3 (which is multiplexer)
    • wiring from logger to multiplexer:
      • SE3 -- CLR -- COM H1
      • SE4 -- BLK -- COM L1
      • AG -- BLK -- COM L2
      • E2 -- RED -- COM H2
    • connected 10m WS to P1 & G via wiring board terminal blocks, at lower left, left to right, from multiplexer to sensor on tower:
      • empty
      • empty
      • mplx 7L2 -- BLK -- WHT to sensor
      • mplx 7H1 -- BLK -- GRN
      • mplx 7H2 -- RED -- BLU
      • CR10X P1 -- RED
      • CR10X G -- BLK
    • spliced sensor-to-4C cable at either end:
      • WHT -- WHT cable 1
      • GRN -- GRN cable 1
      • BLU -- RED cable 1
      • RED -- RED cable 2
      • BLK -- BLK cable 2