Pretrip activities

  • Test out a bit more the thermistor version thermal conductivity probes.
  • Look for more CF cards to leave at NGEE Koug and Teller Bottom.

To Ship

  • XX Actionpackers with equipment
  • XX the snow stand supplies
  • A bit more.

Day 1

  • Fly to Nome
  • Get gear from container
  • XX start batteries charging
  • if time run out to Teller and set up GPS to log at GCP / install new PT for Teller SW / Make a discharge measurement
  • Would be nice to grab the CR6 (& enclosure) from conex and use it in a place with wifi to get CR6 driver installed.

Day x

  • Teller m47 CAS
  • Download Data
  • setup new tiny station
    • precip bucket stand
      • 3x pieces of pipe
      • 2x screed stake
      • 1x three way deal
      • 2x hose clamps
    • hang Airtemp
    • mount tiny solar panel
    • extra battery
    • charge controller
    • radiation shield for new air temp

Day X

  • Visit Teller Basin
    • Download data
    • check level of radiometer & precip buckets
    • change out transducers on snow sensors

Teller CAS Bonus

  • CR800 Logger
  • Tipping bucket
    • stand for it
      • 2pcs 4' 3/4" pipe
      • 1 pcs 2' 3/4" pipe
      • 2 pcs cross mounts
      • 2 pcs hose clamps (I have the length in the wiki someplace I believe)
      • 3 screed stakes
  • Air Temperature
    • need to make
  • Radiation Shield
  • Instrument Box
  • Battery
  • Solar Panel
  • battery box
  • 12v battery leads
  • charge controller

To fix out there

  • New dry pit using other station's hardware?
  • Do something different with their solar panel?


Copied from NGEE Next Visit

Teller 27 General

  • Survey GCP
  • Help

Teller Bottom To Do

  • check level of radiometer
    • (changed desiccant in June)
  • Secure tipping bucket
    • bring out drill
    • bring out self tapping screws, 3x
  • Bring parts to redo snow stand.
  • check level of tipping bucket
Teller Bottom Packing List
  • cordless drill
  • drill bit
  • quick bit for self tapping screws
  • four self tapping screws
  • 2x snow transducer
  • vertical pipe 6' tall for snow stand
  • Hand Tool List
    • Net radiometer level
      • #2 Phillips screw driver (for leveling net radiometer)
      • circle level
    • Radiometer arm level
      • 5/16" nut driver
      • Flat screwdriver
    • Precip bucket beef up
      • 3-4 self tapping screws
      • quick release nut driver for the self tapping screws
      • quick release drill bit
    • snow stand fix (need to review video again.) The vertical pipe looks to be a 1" EMT maybe? so I just need to figure what to replace that with. I should review snow data for max depth, too to settle on sensor height.
      • allen wrenches?
      • 1/2" nut driver & wrench
    • 2x snow transducer swap
      • campbell phillips screw driver
      • campbell flat screw driver

Teller SW To Do

  • Solar Panel Fixes (research in Fairbanks)
  • Deploy second PT
  • don't forget to grab more desiccant
  • Add a snow sensor here?
Teller SW Packing List
  • @Conex Bring out flow meter to make a measurement again.
  • lead weights... Nome or Fairbanks? Review video / the conex tour
  • new pressure transducer
  • PT tube desiccant
  • PT Loose desiccant
  • cable ties
  • maybe a bit of flex conduit
  • For the solar panel fix... need to look at pictures again.!
  • Hand Tools List
    • Pressure Transducer addition
    • wire snake

Teller m47

  • Think hard about getting the solar panel off the ground a bit more
  • Install Tipping bucket
  • new dry soil pit / dig up and replace original
    • add soil moisture probes, too.
  • review what i proposed
    • 4 soil moisture probes
    • air temp
    • second snow sensor
    • batteries
    • solar panel
    • cr800

Council

  • Survey Sigrid / Margaret's sites

NGEE Kougarok

  • Survey GCP
Replace top mast and anemometer
  • Full replacement anemometer
    • potentially could reuse one from storage but will need:
      • propeller (need to order)
      • cable (fairbanks supplies)
      • right size cord grip (I'm sure this is found in my Fairbanks supplies... or the one that's currently broken... )
      • unistrut & 1" pipe & ubolts (try the square ones?)
      • nylock nuts
  • new brown tarp
  • bring out replacement card... could send new program that doesn't save out the soils data any more to increase storage...
  • put soil moisture probe back in ground.
  • I guess remove VATP from program to make the data record last longer.
  • @Conex
    • Ladder (for anemometer fix)
  • @Tools Required
    • 1/2" box wrench / nut driver
    • 5/16" nut driver
NGEE Koguarok Parts Packed in Fairbanks
  • 2 u-bolts for 1" pipe
  • 2 u-bolts for 1.25" pipe
  • 1 pcs CF memory card
  • 1 pcs 1" top pipe
  • 1 pcs propeller, front nut
  • 1 pcs spare anemometer cable
  • --> Brown Tarp?