− | * | + | * need flex conduit/armoring on antenna, AT sensor cables |
+ | * bring snap link/carabiner for white instrument enclosure | ||
= site logs = | = site logs = | ||
+ | |||
+ | == Sept 5, 2008, Emily & Ken == | ||
+ | *tightened guy wires, radiation/SR50 pole was very crooked | ||
+ | *Old SR50 S/n C4798 and distance to ground was variable (125 cm - 149 cm) due to uneven ground | ||
+ | *Installed a new SR50 and moved it 1 foot to the north where the ground was more level | ||
+ | *New SR50 S/N C4789, calibrated by R. Gieck 9/5/08 | ||
+ | *Reloaded new program onto datalogger (failure during transmission via radios) | ||
+ | *Added bark chips under SR50 and trimmed vegetation | ||
+ | *New SR50 distance from sensor to ground is 134.5 average and I put it into the program. | ||
+ | *Program now reads 1.13 cm of snow, an improvement from the previous reading. | ||
+ | *rain gage was leveled, it was very unlevel. | ||
+ | |||
+ | Future tasks: | ||
+ | *bring out one more fence post | ||
+ | *site needs shielding and conduit | ||
+ | |||
+ | == 13 July 2007, Ken I. == | ||
+ | |||
+ | * replaced missing HMP45C | ||
+ | ** S/N C1440027 | ||
+ | ** calibrated April 2007 | ||
+ | * yellow tags on electric fence were already taped | ||
+ | * fence works (ouch) | ||
+ | * site generally looks good | ||
+ | * rain gauge funnel not secured | ||
+ | * no carabiner/screw link on white box; used tie wrap/wire tie | ||
+ | |||
+ | |||
== 9 June 2007, Ken I., Dan R. == | == 9 June 2007, Ken I., Dan R. == |
Latest revision as of 09:27, 17 September 2008
Contents
South White Hills met
site TODO list
- record as-built wiring of soil sensors
- Flex conduit as needed
- need flex conduit/armoring on antenna, AT sensor cables
- bring snap link/carabiner for white instrument enclosure
site logs
Sept 5, 2008, Emily & Ken
- tightened guy wires, radiation/SR50 pole was very crooked
- Old SR50 S/n C4798 and distance to ground was variable (125 cm - 149 cm) due to uneven ground
- Installed a new SR50 and moved it 1 foot to the north where the ground was more level
- New SR50 S/N C4789, calibrated by R. Gieck 9/5/08
- Reloaded new program onto datalogger (failure during transmission via radios)
- Added bark chips under SR50 and trimmed vegetation
- New SR50 distance from sensor to ground is 134.5 average and I put it into the program.
- Program now reads 1.13 cm of snow, an improvement from the previous reading.
- rain gage was leveled, it was very unlevel.
Future tasks:
- bring out one more fence post
- site needs shielding and conduit
13 July 2007, Ken I.
- replaced missing HMP45C
- S/N C1440027
- calibrated April 2007
- yellow tags on electric fence were already taped
- fence works (ouch)
- site generally looks good
- rain gauge funnel not secured
- no carabiner/screw link on white box; used tie wrap/wire tie
9 June 2007, Ken I., Dan R.
- site generally looks good
- radiation pole is firm & true
- bird post broken off from net radiometer, found beneath
- tripod guys are taut
- no HMP sensor; cable cut cleanly, apparently at base of missing sensor
- owl pellets below solar panel; bird droppings on solar panel & battery box
- installed electric fence