Difference between revisions of "NGEE To Do Next Visit"
		
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
		
		
		
		
		
	
| Line 5: | Line 5: | ||
* bring out tap, die, drill, drill bit, screw for teller bottom radiometer.  | * bring out tap, die, drill, drill bit, screw for teller bottom radiometer.  | ||
* also replace cnr4 desiccant since the unit didn't look like it was sealing right with this missing screw.  | * also replace cnr4 desiccant since the unit didn't look like it was sealing right with this missing screw.  | ||
| − | * Bring out additional desiccant?  | + | * Bring out additional desiccant? for box  | 
* Teller SW desiccant replacement  | * Teller SW desiccant replacement  | ||
* Redrill hole for C1 Grid temperature probe  | * Redrill hole for C1 Grid temperature probe  | ||
| Line 13: | Line 13: | ||
** Related: I'm wondering if the delay between measurements should be increased for the thermistor measurements.  | ** Related: I'm wondering if the delay between measurements should be increased for the thermistor measurements.  | ||
** Also related: perhaps add a second string up at teller top?  | ** Also related: perhaps add a second string up at teller top?  | ||
| + | ** sort of some additional homework is that I saw instability in a number of thermistors when measuring up top.  I suspect but haven't verified that this instability is an indicator for the wonky temperatures seen in the data but need to confirm.  | ||
* 6/11/2018 In Fairbanks... down in 106 / the basement there is a box of 12" nails.  Would be good to grab three for the Teller SW solar panel tripod  | * 6/11/2018 In Fairbanks... down in 106 / the basement there is a box of 12" nails.  Would be good to grab three for the Teller SW solar panel tripod  | ||
* Koug M64 Ngee tipping bucket stand is 1" aluminum pipe (verified by photo)  | * Koug M64 Ngee tipping bucket stand is 1" aluminum pipe (verified by photo)  | ||
* Teller Bottom tipping bucket stands: 3/4" aluminum pipe (it appears)  | * Teller Bottom tipping bucket stands: 3/4" aluminum pipe (it appears)  | ||
| + | * I should do some experiments with the thermal conductivity thermistors in office/lab to see if I can reduce the noisiness.  | ||
====Teller SW Flow====  | ====Teller SW Flow====  | ||
| Line 27: | Line 29: | ||
** manual  | ** manual  | ||
* electrical tape  | * electrical tape  | ||
| + | * We (Nathan and I) set up a reach to use for salt slug method discharge estimates.  It seemed to work great... though we haven't worked up the data...  | ||
==== Radiation Level:====  | ==== Radiation Level:====  | ||
Revision as of 11:10, 19 June 2018
Contents
Seward Peninsula
- SR50A transducer replacement (fall activity)
 - bring out one step stool to level teller bottom radiometer.
 - bring out tap, die, drill, drill bit, screw for teller bottom radiometer.
 - also replace cnr4 desiccant since the unit didn't look like it was sealing right with this missing screw.
 - Bring out additional desiccant? for box
 - Teller SW desiccant replacement
 - Redrill hole for C1 Grid temperature probe
 - Measure Creek Flow
 - Re-level radiometers
 - Measure thermistors at Teller Bottom and add them to fieldbook.
- Related: I'm wondering if the delay between measurements should be increased for the thermistor measurements.
 - Also related: perhaps add a second string up at teller top?
 - sort of some additional homework is that I saw instability in a number of thermistors when measuring up top. I suspect but haven't verified that this instability is an indicator for the wonky temperatures seen in the data but need to confirm.
 
 - 6/11/2018 In Fairbanks... down in 106 / the basement there is a box of 12" nails. Would be good to grab three for the Teller SW solar panel tripod
 - Koug M64 Ngee tipping bucket stand is 1" aluminum pipe (verified by photo)
 - Teller Bottom tipping bucket stands: 3/4" aluminum pipe (it appears)
 - I should do some experiments with the thermal conductivity thermistors in office/lab to see if I can reduce the noisiness.
 
Teller SW Flow
- cloth tape
- left a small cloth tape at the site
 
 - metal meter stick or folding tape
- left a metal meter stick at the site
 
 - flow tracker
 - fieldbook
 - YSI conductivity meter
- manual
 
 - electrical tape
 - We (Nathan and I) set up a reach to use for salt slug method discharge estimates. It seemed to work great... though we haven't worked up the data...
 
Radiation Level:
- step ladder
 - a bit of wood to provide better base for step ladder
 - phillips screwdriver for level
 
Radiation Desiccant Swap:
- Step ladder
 - small CSI phillips
 - K&Z desiccant pack
 - anti-corrosion goo
 
Teller Top Soil Temperatures
- Volt meter
 - fieldbook
 
Teller bottom precip bucket swap
- small csi phillips
 - desiccant pack
 - 2 red butt splices
 - toggle bolts
 - 5/16" nut driver
 - 1/2" nut driver / wrench for ubolts
 - crimping tool
 - wire cutter
 
Utqiagvik
- Intensive Site C HMP155 failed
 - Serial to USB Adapter seems to have shorted out recently:
 
[ 375.134145] usb 1-1.5: Manufacturer: Prolific Technology Inc. [ 375.137510] pl2303 1-1.5:1.0: pl2303 converter detected [ 375.152130] usb 1-1.5: pl2303 converter now attached to ttyUSB0 [ 375.585516] usb 1-1-port2: over-current change [ 375.801642] usb 1-1.5: USB disconnect, device number 48 [ 375.805558] pl2303 ttyUSB0: pl2303 converter now disconnected from ttyUSB0 [ 375.805712] pl2303 1-1.5:1.0: device disconnected [ 376.041011] usb 1-1.5: new full-speed USB device number 49 using dwc_otg [ 376.144070] usb 1-1.5: New USB device found, idVendor=0557, idProduct=2008 [ 376.144111] usb 1-1.5: New USB device strings: Mfr=1, Product=2, SerialNumber=0 [ 376.144131] usb 1-1.5: Product: USB-Serial Controller [ 376.144149] usb 1-1.5: Manufacturer: Prolific Technology Inc. [ 376.160012] pl2303 1-1.5:1.0: pl2303 converter detected [ 376.167664] usb 1-1.5: pl2303 converter now attached to ttyUSB0 [ 377.377778] usb 1-1-port2: over-current change [ 377.591631] usb 1-1.5: USB disconnect, device number 49 [ 377.599560] pl2303 ttyUSB0: pl2303 converter now disconnected from ttyUSB0 [ 377.599738] pl2303 1-1.5:1.0: device disconnected [ 377.840992] usb 1-1.5: new full-speed USB device number 50 using dwc_otg [ 377.943953] usb 1-1.5: New USB device found, idVendor=0557, idProduct=2008 [ 377.943995] usb 1-1.5: New USB device strings: Mfr=1, Product=2, SerialNumber=0 [ 377.944014] usb 1-1.5: Product: USB-Serial Controller [ 377.944031] usb 1-1.5: Manufacturer: Prolific Technology Inc. [ 377.947508] pl2303 1-1.5:1.0: pl2303 converter detected [ 377.961018] usb 1-1.5: pl2303 converter now attached to ttyUSB0