Difference between revisions of "2009 August Nome Trip"
Jump to navigation
Jump to search
Line 17: | Line 17: | ||
Anemometer Broke 07/2008 | Anemometer Broke 07/2008 | ||
Install Taylor Anemometer | Install Taylor Anemometer | ||
+ | Add new tower/station | ||
====Anvil Mountain==== | ====Anvil Mountain==== |
Revision as of 15:15, 1 July 2009
Contents
Fairbanks Prep
- 16 HMP45C heads needed for full replacement. Not saying we need to do all of them but for the total out there number it is 16.
- Solder Quick Connects on Net Radiometers to be taken out to the SP.
- Make sure we have enough SR50/SR50A/Judd sonic replacement sensors
Radio Repeater Station Needs:
Troubleshoot 2009 Radio Problems. Specifically: Anvil to Kigluaiks Hop and Skookum to C2 Blueberry Hop.
Kigluaiks
HMP45C requires replacement AT Broke 12/2007 RH Broke 05/2008 Anemometer Broke 07/2008 Install Taylor Anemometer Add new tower/station
Anvil Mountain
HMP45C replace sensor with newly calibrated instrument Install Taylor Anemometer Summer Net radiation?
Skookum Pass
HMP45C replace sensor with newly calibrated instrument
Hydrologic Stations Needs:
Snake River
Replace Battery Install surface and subsurface temperature sensors for ET calcs Summer net radiation wind speed for ET calcs
Meteorological Station Needs:
C1 Grid
HMP45C replace sensor with newly calibrated instrument @ 1m, 3m Replace SR50A Transducer Install Snow temperature array for Saito? Solder on (@site) quick connects for Net Radiometer
C2 Blueberry
HMP45C replace sensor with newly calibrated instrument @ 1m, 3m, 10m 10m HMP45C Failed 12/2008 Replace Judd Transducer Reinstall calibrated LW & SW Radiometers, bring machine screws from Fairbanks for fixing radiometers to stand. Bring out soldering iron incase LW/SW cables have cracked over winter. Replace Precip Bucket Solder on (@site) quick connects for Net Radiometer
K1 Burn
HMP45C replace sensor with newly calibrated instrument @ 1m, 3m Replace SR50A Transducer Fix Soil Temperature problem: + bring out replacement AM416 + bring out precision resistors Solder on (@site) quick connects for Net Radiometer
K2 Met
HMP45C replace sensor with newly calibrated instrument @ 1m, 3m, 10m Replace Judd Transducer Reinstall calibrated LW & SW Radiometers Bring out soldering iron incase LW/SW cables have cracked over winter. Solder on (@site) quick connects for Net Radiometer Install Snow Temperature array for Saito?
K3 Mauze