Difference between revisions of "2009 August Nome Trip"

From IARC 207 Wiki
Jump to navigation Jump to search
Line 1: Line 1:
Radio Repeater Station Needs:
+
===Radio Repeater Station Needs:===
  
Kigluaiks  
+
====Kigluaiks====
 
  HMP45C requires replacement  
 
  HMP45C requires replacement  
 
  AT Broke 12/2007
 
  AT Broke 12/2007
Line 8: Line 8:
 
  Install Taylor Anemometer
 
  Install Taylor Anemometer
  
Anvil Mountain
+
====Anvil Mountain====
 
  HMP45C replace sensor with newly calibrated instrument
 
  HMP45C replace sensor with newly calibrated instrument
 
  Install Taylor Anemometer
 
  Install Taylor Anemometer
 
  Summer Net radiation?
 
  Summer Net radiation?
  
Skookum Pass
+
====Skookum Pass====
 
  HMP45C replace sensor with newly calibrated instrument
 
  HMP45C replace sensor with newly calibrated instrument
  
Hydrologic Stations Needs:
+
===Hydrologic Stations Needs:===
  
Snake River
+
====Snake River====
 
  Replace Battery
 
  Replace Battery
 
  Install surface and subsurface temperature sensors for ET calcs
 
  Install surface and subsurface temperature sensors for ET calcs
Line 24: Line 24:
 
  wind speed for ET calcs
 
  wind speed for ET calcs
  
Meteorological Station Needs:
+
===Meteorological Station Needs:===
 +
====C1 Grid====
 +
HMP45C replace sensor with newly calibrated instrument @ 1m, 3m
 +
Replace '''SR50A''' Transducer
 +
Install Snow temperature array for Saito?
 +
Solder on (@site) quick connects for Net Radiometer
 +
 
 +
====C2 Blueberry====
 +
HMP45C replace sensor with newly calibrated instrument @ 1m, 3m, 10m
 +
10m HMP45C Failed 12/2008
 +
Replace Judd Transducer
 +
Reinstall calibrated LW & SW Radiometers, bring machine screws from Fairbanks for fixing radiometers to stand.
 +
Bring out soldering iron incase LW/SW cables have cracked over winter.
 +
Replace Precip Bucket
 +
Solder on (@site) quick connects for Net Radiometer
 +
 
 +
====K1 Burn====
 +
HMP45C replace sensor with newly calibrated instrument @ 1m, 3m
 +
Replace '''SR50A''' Transducer
 +
Fix Soil Temperature problem:
 +
  + bring out replacement AM416
 +
  + bring out precision resistors
 +
Solder on (@site) quick connects for Net Radiometer
 +
 
 +
====K2 Met====
 +
HMP45C replace sensor with newly calibrated instrument @ 1m, 3m, 10m
 +
Replace Judd Transducer
 +
Reinstall calibrated LW & SW Radiometers
 +
Bring out soldering iron incase LW/SW cables have cracked over winter.
 +
Solder on (@site) quick connects for Net Radiometer
 +
Install Snow Temperature array for Saito?
 +
 
 +
====K3 Mauze====
 +
HMP45C replace sensor with newly calibrated instrument @ 1m, 3m
 +
Replace '''SR50''' Transducer
 +
Solder on (@site) quick connects for Net Radiometer

Revision as of 12:00, 10 April 2009

Radio Repeater Station Needs:

Kigluaiks

HMP45C requires replacement 
AT Broke 12/2007
RH Broke 05/2008
Anemometer Broke 07/2008
Install Taylor Anemometer

Anvil Mountain

HMP45C replace sensor with newly calibrated instrument
Install Taylor Anemometer
Summer Net radiation?

Skookum Pass

HMP45C replace sensor with newly calibrated instrument

Hydrologic Stations Needs:

Snake River

Replace Battery
Install surface and subsurface temperature sensors for ET calcs
Summer net radiation
wind speed for ET calcs

Meteorological Station Needs:

C1 Grid

HMP45C replace sensor with newly calibrated instrument @ 1m, 3m
Replace SR50A Transducer
Install Snow temperature array for Saito?
Solder on (@site) quick connects for Net Radiometer

C2 Blueberry

HMP45C replace sensor with newly calibrated instrument @ 1m, 3m, 10m
10m HMP45C Failed 12/2008
Replace Judd Transducer
Reinstall calibrated LW & SW Radiometers, bring machine screws from Fairbanks for fixing radiometers to stand.
Bring out soldering iron incase LW/SW cables have cracked over winter.
Replace Precip Bucket
Solder on (@site) quick connects for Net Radiometer

K1 Burn

HMP45C replace sensor with newly calibrated instrument @ 1m, 3m
Replace SR50A Transducer
Fix Soil Temperature problem: 
  + bring out replacement AM416
  + bring out precision resistors
Solder on (@site) quick connects for Net Radiometer

K2 Met

HMP45C replace sensor with newly calibrated instrument @ 1m, 3m, 10m
Replace Judd Transducer
Reinstall calibrated LW & SW Radiometers
Bring out soldering iron incase LW/SW cables have cracked over winter.
Solder on (@site) quick connects for Net Radiometer
Install Snow Temperature array for Saito?

K3 Mauze

HMP45C replace sensor with newly calibrated instrument @ 1m, 3m
Replace SR50 Transducer
Solder on (@site) quick connects for Net Radiometer