Dfm1
Revision as of 18:12, 31 July 2007 by 137.229.33.196 (talk)
Contents
South White Hills met
site TODO list
- record as-built wiring of soil sensors
- Flex conduit as needed
- need flex conduit/armoring on antenna, AT sensor cables
- bring snap link/carabiner for white instrument enclosure
site logs
13 July 2007, Ken I.
- replaced missing HMP45C
- S/N C1440027
- calibrated April 2007
- yellow tags on electric fence were already taped
- fence works (ouch)
- site generally looks good
- rain gauge funnel not secured
- no carabiner/screw link on white box; used tie wrap/wire tie
9 June 2007, Ken I., Dan R.
- site generally looks good
- radiation pole is firm & true
- bird post broken off from net radiometer, found beneath
- tripod guys are taut
- no HMP sensor; cable cut cleanly, apparently at base of missing sensor
- owl pellets below solar panel; bird droppings on solar panel & battery box
- installed electric fence