  • Replaced Tower LI7200 and updated calibration & software both on unit and windows version
  • reconnected power and tubing and everything looks good to me.
  • removed fores floor LI7200
  • removed forest floor CNR4
  • added newly calibrated CNR4 to forest floor tripod
  • sent new program with updated calibration coefficients for this CNR4 to the data logger
  • left forest floor li7200 wires in place but covered with a bag
  • for tools needed:
    • phillips screwdriver
    • campbell phillips screwdriver
    • campbell flat screwdriver
    • crescent wrench
    • pocket scissors
    • electrical tape
  • left the vertical stud for the li7200 installed.
    • the machine screws for it are in the shed on the forest floor toughbook
    • brought back to town the air intake for this to keep it out of the weather.
  • The tower wifi antenna needs replacing. Do this next visit. The coax is weathered and fraying.