2016 NGEE August Nome Trip
		
		
		
		
		
		
		Jump to navigation
		Jump to search
		
		
		
		
		
		
		
	
Contents
Second Trip:
August 11 - 19
pre eve trip to do
- prepare data/power/ground common connections for SDI devices
 - prepare HMP155 cables for old sites.
 
To Purchase
- One Compact flash card for CFM100
 
Second Trip To Do List:
Teller
- @ Teller
- Teller Lower Station turn into full met 3m tripod located closer to shrubs
- soil pit
- soil moisture @ 5, 10, 20, 30, 40 cm bgs
 - soil thermal conductivity @ 10, 20, 30, 40 cm bgs
 - soil temperature @ 10, 20, 30, 40 cm bgs
 - soil heat flux near base of active layer & plant / soil boundary
 - take 2-3 soil samples from this pit for soil moisture testing
 
 - 1.5m soil temperature profile
 - snow depth @ tripod
 - snow depth away from tripod
 - interval camera
 - 4 component radiation
 - Spectral response sensors: NDVI & PRI up looking and two vegetation communities
 - 1.5m Air temperature, Relative Humidity, & Dew Point Temperature
 - Wind speed and direction at 3m
 - summer precipitation
- bring out self tapping screw to keep animals from removing precip bucket lid.
 
 
 - soil pit
 - Surface Water Station #1
- Bring out CR200 (May go with CR800 if Ross can't get the data retrieval program working with the CR200... then CR200 for next year).
- another reason to go CR800 is that this could become the satellite base and there wouldn't be the pinch on the control ports.
 
 - Connect two Pressure Transducers to this CR200
 - Readdress them to 1 & 0 from 0 & 0
 - From temporary top site bring down for SW station:
- instrument box
 - battery
 - solar panel
 - charge controller
 
 
 - Bring out CR200 (May go with CR800 if Ross can't get the data retrieval program working with the CR200... then CR200 for next year).
 - Teller Upper Station 
- soil pit in the low area
- soil moisture @ 5, 10, 20, 30, 40 cm bgs
 - soil thermal conductivity @ 10, 20, 30, 40 cm bgs
 - soil temperature @ 10, 20, 30, 40 cm bgs
 - soil heat flux near base of active layer & plant / soil boundary
 - take 2-3 soil samples from this pit for soil moisture testing
 
 - 1.5m soil temperature profile
 - snow depth @ tripod
 - snow depth away from tripod
 - interval camera
 - 4 component radiation
 - 1.5m Air temperature, Relative Humidity, & Dew Point Temperature
 - Wind speed and direction at 3+m
 - summer precipitation
 - super animal protect this site.
 
 - soil pit in the low area
 
 - Teller Lower Station turn into full met 3m tripod located closer to shrubs
 
Teller Extras:
- Survey in and place the two hobo pressure transducers somewhere in the watershed up stream from the main site.
 - Survey in temporary and permanent tripods / instrumentation
 - Discharge measurement @ bottom
 
Existing Site @ Kougarok
- K Met
- Tower change size reduction
 - To bring:
- pipe cutter
 - replacement bolts for tower sections
 - rope along
 
 - complicators (I think Council will be slightly simpler)
- unistrut at base
 - tower sinking into muck
 - instrument box with all instruments at base
 - cross arms & junk hanging off structure
 
 - Level radiometer platform & then radiometers
 - To bring:
- dog anchor (I think we used a dog anchor last summer actually... this will be the see the results of that check)
 - cable cutter
 - additional cable thimbles
 - tools
 - sketch out could we use like a solid unistrut arm rather than the cable
 
 - level precip bucket
- level
 
 - Snow sensor replacement
- SR50A w/ address 0
 
 - Refresh AT/RH sensors
- program change
 
 - check if Anemometers are still within specification
 - replace snow sensors
 - download data off storage module (there is a setting to be accessed in LN setup)
 - only planning to visit 10 meter tower and Mauze Gulch (up from bridge)
 - bring out new battery
 - copy of permit or # on metal tag?
 
 - K3 Mauze Gulch
- bring out new battery
 - bring out SR50A w/ address 0
 - copy of permit or # on metal tag?
 - level precip bucket
- level
 
 - Refresh AT/RH sensors
- program change
 
 - check if Anemometers are still within specification
 
 - @ airport conex
- see about drilling a hole in the unit so a radio / satellite base can be setup... or think about this for K2
 
 
Existing Sites @ Council
- Blueberry Hill
- Remove lowest section of Tower? @ blueberry hill
 - Level radiometers
- pretty sure no dog anchor here but could look into it...
 - oh, could try 1/2 unistrut plus the small ubolts
 
 - level precip buckets
 - Refresh AT/RH sensors
 - check if Anemometers are still within specification
 - download data
 - spend two nights with Mike Murphy to maximize field time
 - put in ground control point & log position overnight
 - Bring out new battery
 
 
- Existing Skookum Pass Repeater site
- Switch old data logger out for CR800 and
 - if time install redundant satellite link
 - bring up two batteries
 
 
- Existing Anvil Mountain Repeater site
- bring up two batteries
 - Change AT/RH/DP out for simpler Air temperature only
 
 
8/11
- Arrive @ around Noon
 - Pick up vehicle. confirmation number 39289
 - Pick up freight
 - Visit Anvil Mountain and swap out batteries.
 - Get groceries
 - Pack vehicle for 8/12
 - Pick up freight
- bring teller coded gear to Bering Air
 
 
8/12 - 8/14 or 15
(I think this may take more than two days)
Starting to think 1.5 -2 days per site is more realistic
- Go to Teller
 - @Top Put up permanent site
- see above for instrumentation etc
 
 - @ SW station
- see above for instrumentation etc
 
 - @ Snowmelt Logger
- see above for instrumentation etc
 
 - Use Survey GPS to lock in positions of all instrumentation (before move and after!)
 - Make a discharge measurement
 - Level precipitation gage
 - Bring a drill & self-tapping screw to lock tipping bucket in place.
 
8/14 - 8/16
- FUEL UP!!!!
 - If the weather cooperates, hike up and visit the Kigluaiks Sites
- optional / cancel if behind schedule...
 - download data
 - reorient antenna if needed
 
 - Plan A: Recon the Kougarok site
 - Plan B: save Kougarok_m64 site for '17
 - Plan C: put some instruments @ Pilgrim hot springs?
 - @Kougarok_m64
 - see above for instrumentation etc
 - @ K2 Met
- grab data off the storage module
 - sensor refresh
 - Battery
 
 - @ K3 Mauze Gulch
- Sensor refresh
- AT/RH
 - SR50A
 - Battery
 
 - Data Download
 
 - Sensor refresh
 - Camping Schedule on ideal itinerary
- 8/15: Kougarok Cabin
 - 8/16: Kougarok Cabin
 
 
8/17 - 8/18
- Drive back to Nome
 - FUEL UP!!!!
 - Drive out to Council
 - Spend two nights @ B&B.
 - Focus on C2 Blueberry site & Tower.
 - make the radiation stand more solid.
 - Reduce the tower to 2 sections
 
8/19
- Return to Nome
 - On way stop by Skookum Pass repeater
 - Fix as noted above.
 - Ship anything in need of shipping
- crab?
 
 - depart for Fairbanks in evening
 
To bring MISC
- anti seize goop
 - camping gear
 - putty for boxes
 - rope-a-long
 
Hydra Probe notes
- ID 0 = 5cm = red
 - ID 1 = 10cm = orange
 - ID 2 = 20cm = purple
 - ID 3 = 30cm = brown
 - ID 4 = 40cm = black
 
VATP notes
- bringing 2 drill bits (different tips), two extensions (different lengths), and two connectors
 - also need to bring wrenches
 - drill in UAF Nome storage
 - when installing VATP, remove upper veg layer, drill a hole, install VATP, cut a slit in upper layer to place back around installed probe
 - use white duct tape to secure probe to conduit
 
Anemometer notes
Testing each anemometer for
- propeller torque using anemometer torque disc (18310)
- factory spec is 2.6 gm-cm (black nylon screw at 5cm and metal screw at 2cm)
- 33821 moved with 0.2 gm-cm (a black nylon screw at 2cm radius), so this is much better than factory spec
 - 61996 moved with 0.5 gm-cm
 
 - tested both Clock Wise(CW) and Counter Clock Wise (CCW)
 
 - factory spec is 2.6 gm-cm (black nylon screw at 5cm and metal screw at 2cm)
 - Wind speed using anemometer drive (18802)
- @200rpm = 0.98m/s. @1000rpm = 4.9m/s. @2000rpm = 9.8m/s
 - tested both CW and CCW
 
 - Vane Torque using Vane Torque Gauge (18331)
- mount the gauge, pull the string, if it moves with < 30 gm-cm of torque, golden.
 - tested both CW and CCW
 
 - Wind Direction using Vane Angle Fixture Tower Mount (18212)
- checked 3 directions
- 33821 all within 1 degree of accuracy
 - 61996 reads 3 degrees less (ex: reads 177 when should be 180)
 
 
 - checked 3 directions
 
Outstanding To Do Items
- Grab remaining bolts for upper tripod
 - cut unistrut for green box to upper tripod interface
 - sort hose clamps for:
- teller upper snow stand
 - teller upper precip stand
 - teller lower precip stand
 - any others...
 - solder extensions for TL Upper & TL Lower snow stand SR50A cable
 - set up terminal blocks for SDI instruments (power, data, ground)
 - heat flux constants:
- S/N 7880: 55.58 uV/(W/m^-2)
 - S/N 7878: 59.63 uV/(W/m^-2)
 - S/N 12090: 62.88 uV/(W/m^-2) (TL Upper)
 - S/N 12121: 63.39 uV/(W/m^-2) (TL Lower)
 
 - Bring precision resistors
 - toolbag
 - solder HMP155 extensions for old sites
 - pack up RM Young hardware
 - Rope-a-long
 
 
- CF Card for CFM100(s)